BRK electronic CO5120B Smoke Alarm User Manual


 
13
SINGLE-STATION INSTALLATION
Tools needed: Standard/Flathead screwdriver.
DANGER!
ELECTRICAL SHOCK HAZARD. Turn off
power to the area where you will install this
unit at the circuit breaker or fuse box before
beginning installation. Failure to turn off the
power before installation may result in serious
electrical shock, injury or death.
To install this unit:
1. Remove the mounting bracket from the base.
Position the screw slots on the mounting
bracket over the screws in the junction box.
Tighten the screws.
2. Using wire nuts, connect the
power connector to the AC power.
Connect the white wire on the
power connector to the neutral
wire in the junction box.
Connect the black wire on the
power connector to the hot wire
in the junction box.
Tuck the violet wire inside the
junction box.
It is used for
interconnect only.
3. Plug the power connector into
the back of the CO alarm.
4. Position the base of the alarm
over the mounting bracket and
turn. The alarm can be
positioned over the bracket every 60°. Turn the
unit clockwise (right) until the unit is in place.
5. If you are only installing one unit, restore
power to the junction box.
6. Make sure the unit is receiving AC power.
Under normal operation, the red indicator
light will shine continuously.
7. If the red power indicator light does not light,
TURN OFF POWER TO THE JUNCTION BOX
and recheck all connections. If all connections
are correct and the red power indicator still
does not light when you restore the power,
the unit should be replaced immediately.
DANGER!
ELECTRICAL SHOCK HAZARD. Do not
restore power until all CO alarms are
completely installed. Restoring power before
installation is complete may result in serious
electrical shock, injury or death.