BRK electronic C05120PDBN Carbon Monoxide Alarm User Manual


 
brkelectronics.com
ARCHITECTURAL AND ENGINEERING SPEC
INSTALLATION OF ALARM
The carbon monoxide alarm shall be a BRK Model CO5120PDBN and shall provide at a
minimum the following features and functions:
1. An electrochemical CO sensor and an LCD multifunction digital display with peak
CO level memory capability.
2. Powered by 120V AC, 60Hz and have a monitored 9V battery backup and a solid
state piezo horn rated at 85dB at 10 ft. and shall be capable of self restoring.
3. The unit shall perform self diagnostic tests and issue a malfunction warning both
audibly (three chirps) and visually (“Err” in display) if the unit malfunctions.
4. The unit shall have an "End of Life" signal. This signal should be capable of
temporarily being silenced for up to 2 days. After about 2 days, the signal will
resume. After about 2-3 weeks the signal cannot be silenced.
5. A visual LED power-on indicator to confirm unit is receiving power or to confirm
unit has switched to battery backup mode. In battery backup mode, digital
display indicates “bAt”; “bAt” indication will flash if battery is weak or missing.
6. The CO sensor is adjusted not to detect CO levels below 30 PPM and will not
alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm
at the following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO
between 10 and 50 minutes and 70 PPM CO between 60 and 240 minutes.
7. A test/silence button to check all alarm functions and to silence any nuisance
alarms. In addition, the unit shall have a low battery silence feature to quiet the
low battery chirp for up to eight hours.
8. A “Smart Interconnect” feature allows the unit to be interconnected to BRK
smoke alarms. During a smoke event, the CO5120PDBN horn pattern shall emit
the smoke alarm horn pattern (3 beeps, pause, 3 beeps pause). During a CO event,
the interconnected CO alarms sound their normal horn pattern.
9. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and
relative humidity between 10% and 95%.
10. The unit shall at a minimum meet the requirements of UL2034, NFPA 720 and ICC.
SHIPPING SPECS:
TECHNICAL SPECS
Individual Carton Dimensions 5.54"L x 2.10"W x 5.72"H
Weight 0.61 lbs.
Cube 0.038 ft3
UPC 0 29054 85619 7
Master Carton Dimensions 13.13"L x 5.81"W x 12.13"H
Master Pack 12
Weight 9.2 lbs.
Cube: 0.54 ft3
I2 of 5: 400 29054 85619 5
Pallet Information
Cases per Layer 25
Number of Layers: 3
Cases per Pallet: 75
Units per pallet: 900
Cube: 47.3 ft3
Weight: 758 lbs.
Alarm Dimensions: 5.4” dia x 1.9”H
Weight: 7.3 oz
Operating Voltage: 120V AC 60Hz w/ 9V battery backup
Operating Current: .09 amps (standby/alarm)
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates carbon
monoxide condition, causing the unit to alarm
Press and hold test/silence button
Alarm Reset: Automatic when CO clears
Interconnections: Up to 18 units of First Alert or BRK Smoke, CO and
Heat Alarms. Maximum of 12 smoke alarms. See
user’s manual for details.
CO Sensor: Electrochemical
Indicator Lights/Sounds:
AC Power: Constant Green LED, Display: blank
DC Power: Intermittent Green LED, Display: "bAt"
Local Alarm: Red LED flashes rapidly, Display: CO level in PPM
Remote Alarm: Red LED out. Display: blank
Latching Alarm: Red LED flashes every 5 seconds after local alarm stops
Listing: Listed to UL2034 Standard
©2010 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM3076
5.4"
TOP VIEW SIDE VIEW
1.9"
CAT.
CO5120PDBN
THE PARTS OF THIS CO ALARM
MOUNTING
BRACKET
Installation of this carbon monoxide alarm must conform to all
local electrical codes and Article 760 of the National Electrical
Code (NFPA 70) and NFPA 72. Interconnected units must meet
the following requirements: Total length of wire interconnecting
units should be less than 1000 feet, be #18 gauge or larger and
be rated at least 300V. It is recommended that all units be on the
same fuse or circuit breaker. If local codes do not permit, be sure
the neutral wire is common to both phases.
1
2
3
5
6
4
2
3
9
7
8
CO
BATTERY DRAWER LOCK
Remove Pin
Push locking pin through
hole near battery drawer
on the back of the alarm.
678
43 1
5 2
A
B
}
}
43 15
1. Mounting bracket
2. Mounting Slots
3. Locking Pins
4. Hot (Black) AC Wire
5. Nuetral (White) AC Wire
6. Interconnect (Orange) Wire
7. Battery Drawer Latch
8. Battery Drawer - Install
9V battery here
9. Quick-Connect Plug
A. Unswitched 120VAC 60 Hz source
B. To additional units; Maximum = 18 total
(Maximum 12 Smoke Alarms)
1. CO Alarm 5. Junction Box
2. Ceiling or Wall 6. Neutral Wire (White)
3. Power Connector 7. Interconnect Wire (Orange)
4. Wire Nut 8. Hot Wire (Black)