Breckwell P4000 Stove User Manual


 
SPECIFICATIONS
Width: 25 ¼”
Height: 29 ½”
Depth: 24 ¼”
Weight: 340 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 40 lbs.
(this can vary widely depending on pellet size, length, and
diameter)
EPA status: exempt
Burn time: 1 lb. to 4 ½ lbs. per hour
BTU range: 8,200 to 40,000
Approved installations: mobile home, alcove, conventional
PREPARATION
Factory packaging must be removed, and some minor assembly
work is required prior to installation. Access to the rear of the
stove is necessary.
NOTE: Normally, your dealer will perform these functions.
CLEARANCES
The Breckwell P4000 has been tested and listed for installation in
residential, mobile home and alcove applications.
FLOOR PROTECTION: Freestanding installations, minimum
27 ¼” wide by 33 ¼” deep. The stove must be placed on a
continuous (grouted joints) noncombustible material such as
ceramic tile, cement board, brick, 3/8” millboard or equivalent, or
other approved or listed material suited for floor protection.
THE MATERIAL(S) USED MUST HAVE, OR COMBINE TO
HAVE, A MINIMUM INSULATIVE RATING OF ‘R1’.
NOTE: ceramic tile, or any tile, requires a continuous sheet
beneath to prevent the possibility of embers falling through to the
combustible floor if cracks or separation should occur in the
finished surface, this would include floor protection for Built-in
raised hearths. Check local codes for approved alternatives.
Clearances are measured from the sides, back and face (door
opening) or stove body (refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES
IN THE INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.