Breckwell P23FSA Stove User Manual


 
INSERT INSTALLATIONS
Insert installations must be vented with 3” or 4” pipe. Pipe may
be single wall stainless steel flexible pipe. Vent may terminate
within chimney beyond a blanking plate or extend to the chimney
top. See “COMBUSTION AIR SUPPLY” for outside air access
information.
The fireplace and chimney should be cleaned thoroughly before
starting the installation. We suggest painting the interior of
particularly old and dirty fireplaces to seal any odors. In zero-
clearance fireplace installations, when the fireplace opening is
above the floor or raised hearth, the adjustable “Breckwell P23 Z-
C Legs” (part # A-S-ZCLEGS) can be used to bridge the gap
between the hearth and stove bottom. (Refer to figure 14)
A. ASSEMBLING THE FLASHING SET
Follow the instructions packaged with the P23 Flashing set part
C-P23-MEDFL-C or C-P23-LGFL-C.
(Refer to Figure 15)
FIGURE 14
FIGURE 15
INSTALLATION
11