SPECIFICATIONS
Width: 23 1/8”
Height: 30 ½”
Depth: 22 ¼”
Weight: 233 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 50 lbs.
(This can vary widely depending on pellet
size, length, and diameter)
EPA status: exempt
Burn time: 1 lb. to 5.5 lbs. per hour
BTU range: 8,200 to 50,000
Approved installations: mobile home, alcove,
conventional
PREPARATION
Factory packaging must be removed, and
some minor assembly work is required prior
to installation. Access to the rear of the
stove is necessary.
NOTE: Normally, your dealer will perform
these functions.
CLEARANCES
The Breckwell P2700 Freestanding has
been tested and listed for installation in
residential, mobile home and alcove
applications.
FLOOR PROTECTION: Freestanding
installations, minimum 24” wide by 29” deep.
The stove must be placed on a continuous
(grouted joints) noncombustible material
such as ceramic tile, cement board, brick,
3/8” millboard or equivalent, or other
approved or listed material suited for floor
protection. NOTE: ceramic tile, or any tile,
requires a continuous sheet beneath to
prevent the possibility of embers falling
through to the combustible floor if cracks or
separation should occur in the finished
surface, this would include floor protection
for Built-in raised hearths. Check local codes
for approved alternatives.
Clearances are measured from the sides,
back and face (door opening) or stove body
(refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS
OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES
SPECIFIED BY THE VENT
MANUFACTURER.
INSTALLATION
5
FIGURE 1
FIGURE 2
FLOOR PROTECTION
(MINIMUM 24” W X 29” D)
FIGURE 3