Bradford-White Corp Through the wall Gas water Heaters Water Heater User Manual


 
Thermal Well Testing
P
osition gas valve power
s
witch to the “OFF”
position and disconnect
thermal well harness from
gas control.
N
Y
Using a multi-meter set to the ohms setting, insert one meter probe into center wire
position of thermal well connector, insert the second probe into either of the outside
wire positions (see photo 19).
Alternate the probe on the outside position to the opposite outside wire position
(see photo 20).
Replace thermal well
(see page 26)
Using a multi-meter set to
the Ohms setting,
determine the resistance of
thermal well sensors 1 & 2
(see photos 19 & 20)
Disconnect thermal
well wire harness
19
20
Thermal well OK
TTW SERVICE PROCEDURE VI
Gas Control/Thermal Well Testing and
Replacement
Page 24
Gas Control Testing
See pages 29 & 30 for gas control
input & output testing.
Once the thermal well resistance values are known, the water
temperature must also be known to determine if the resistance
values are correct. See page 25 to obtain water temperature.
Are thermal well resistance values correct?
pg24.pdf 1pg24.pdf 1 3/24/06 4:06:09 PM3/24/06 4:06:09 PM
Page 24