8. Remove the plastic cover from the PCB and electrical connections.
9. Thread the cable through the access hole at the base of the water heater and connect the wires
to the control terminals on the right hand side of the PCB.
10. Secure the control cable using the clamp provided in the control compartment.
11. Replace the plastic cover over the PCB terminals and then replace the front control panel of the
water heater.
INITIAL OPERATION AND TESTING OF CONTROLS (INSTALLER ONLY)
1. Turn on power to the water heater and fully open a hot water tap.
2. Check the operation of the water heater. Check the operation of the remote temperature
control(s). Check the operation of the power failure protection system (drain solenoids).
3. Explain the proper operation of the new Bradford White EverHot
water heater to the end user.
WARNING
Do not attempt to connect the controls with the power on to the water heater. There is 120 volt
terminals and wiring next to the remote control connections inside the unit. All servicing and wiring
must be performed by a qualified installer.
WARNING
When the water heater or remotely located remote control is used in public use applications, it shall
be installed in a location where it cannot be adjusted by the public (i.e. a maintenance room or
manager’s office). Unauthorized adjustments may result in scalding conditions.
CABLE CLAMP
REMOTE
CONTROL CABLE
REMOTE CONTROL
CONNECTION TERMINALS
Figure 15. Illustration Showing Where to Connect Remote Control Harness.