Single Wall Energy Saver Models
M
eet or exceed ASHRAE 90.1b (current standard)
M
odel
Number
A
pprox.
S
hipping
Weight
lbs.
A
F
loor to
Heater
T
op
in.
C
F
loor to
T&P
C
onn.
in.
B
J
acket
Dia.
in.
C
apacity
SW-2-30-L
SW-2-40R-L
SW-2-50R-L
SW-2-65-L
SW-2-80-L
S
W-2-120-L
U
.S.
Gal.
30
38
48
60
75
1
16
I
mp.
Gal.
25
32
40
50
62
9
7
33
5
/8
41
1
/8
46
1
/4
59
1
/4
59
6
2
1
/2
28
1
/4
34
3
/8
40
1
/8
53
1
/8
52
7
/8
5
5
3
/4
140
172
180
196
224
3
55
22
22
22
22
24
2
8
1
/4
E
F
loor to
Exchanger
O
utlet
in.
5
3
/8
5
3
/8
5
3
/8
5
3
/8
5
3
/8
6
3
/8
27
1
/2
27
1
/2
27
1
/2
27
1
/2
27
1
/2
2
8
1
/2
34
3
/8
41
7
/8
47
60
59
3
/4
6
3
1
/4
D
F
loor to
Water
C
onn.
in.
M
odel
Number
A
pprox.
S
hipping
Weight
kg.
A
F
loor to
Heater
T
op
mm.
C
F
loor to
T&P
C
onn.
mm.
B
J
acket
Dia.
mm.
C
apacity
S
W-2-30-L
S
W-2-40R-L
S
W-2-50R-L
S
W-2-65-L
S
W-2-80-L
S
W-2-120-L
L
iters
1
14
1
43
1
82
2
27
2
84
4
39
8
54
9
14
1
175
1
505
1
499
1
588
7
18
8
73
1
019
1
349
1
343
1
416
6
4
7
7
8
2
8
9
1
02
1
61
5
59
5
59
5
59
5
59
6
10
7
18
E
F
loor to
Exchanger
O
utlet
mm.
1
37
1
37
1
37
1
37
1
37
1
62
F
F
loor to
Exchanger
I
nlet
in.
F
F
loor to
Exchanger
I
nlet
mm.
6
99
6
99
6
99
6
99
6
99
7
20
11
1
/2
11
1
/2
11
1
/2
11
1
/2
11
1
/2
1
1
1
/2
G
F
loor to
Aquastat
in.
G
F
loor to
Aquastat
mm.
2
92
2
92
2
92
2
92
2
92
2
92
8
73
1
064
1
194
1
524
1
518
1
607
D
F
loor to
Water
C
onn.
mm.
Residential PowerStor
®
Indirect Water Heater
General
All units ar
e certified at 300 PSI (2068 kPa) test pressure
and 150 PSI (1034 kPa) working pressure. All potable water connections are 3/4" (19mm) NPT on 8" (203mm) centers.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
T
oxic chemicals, such as those used for boiler tr
eatment, shall NEVER be intr
oduced into the potable side of this system. The potable side may NEVER be
connected to any existing heating system or component(s) pr
eviously used with a non-potable water heating appliance.
Based on 200°F boiler water temperature and 50°F
potable water inlet.
Printed in U.S.A.
554-B-0508-A
©2008, Bradford White Corporation. All rights reserved.
Ambler
, PA
For U.S. and Canada field ser
vice, contact your pr
ofessional installer or local Bradfor
d White sales r
epresentative.
Sales 800-523-2931
Fax 215-641-1670 / T
echnical Suppor
t
800-334-3393
Fax 269-795-1089
W
ar
ranty
800-531-2111
Fax 269-795-1089
International:
Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / T
echnical Suppor
t
866-690-0961 / 905-238-0100
Fax 905-238-0105 / www
.bradfor
dwhite.com
M
odel
N
umber
1
40°F 115°F
DOE Water Heater Performance
SW-2-30-L
SW-2-40R-L
SW-2-50R-L
SW-2-65-L
SW-2-80-L
SW-2-120-L
1
Maximum First
H
our Rating
(Gal.) @
279
288
297
306
321
357
429
438
447
456
470
507
1
40°F 115°F
4.2
4.2
4.2
4.2
4.2
4.2
6.7
6.7
6.7
6.7
6.7
6.7
Continuous
D
raw Rating
(Gal./Min.) @
AApproximate
B
oiler Output
Needed for
Ratings (BTU/Hr.)
220,000
220,000
220,000
220,000
220,000
220,000
5
Model
Number
I=B=R Water Heater Ratings
SW-2-30-L
SW-2-40R-L
SW-2-50R-L
SW-2-65-L
SW-2-80-L
SW-2-120-L
1
First Hour
Delivery
@ 135°F
(Gal.)
255
260
265
275
295
315
Continuous
Draw Rating
@ 135°F
(Gal./Hr.)
A
235
235
235
235
235
235
Standby
Heat Loss
Rating
(°F/Hr.)
1.2
1.1
0.9
0.8
0.6
0.4
Minimum
Heat Source
Flow Rate
(Gal./Min.)
13.7
13.7
13.7
13.7
13.7
13.7
Minimum
Output Rate
of Heat Source
(BTU/Hr.)
157,000
157,000
157,000
157,000
157,000
157,000
5
D
A
F
E
G
C
B
D
A
F
E
G
C
B
POTABLE
CONNECTIONS
ANODE RODS
(TYPICAL)
(
TYPICAL)
These cer
tified ratings wer
e obtained with a heat source output
rate and flow rate as specified and a 180
°
F boiler water supply
temperatur
e. Other r
esults will be obtained under dif
ferent
conditions.