Bradford-White Corp S-SW2-115R6DS Water Heater User Manual


 
G
ENERAL INFORMATION
Upper thermostat
Surface Mount
With
ECO (high limit)
89T Series
Manual
ECO (high limit)
Reset button
Temperature
control Dial
Lower thermostat
Surface Mount
59T Series
Surface Mounted Thermostats
Surface mounted thermostats are mounted into a bracket which holds the thermostat against the side of the tank.
Surface mounted thermostats respond to tank surface temperatures to sense a call for heat, set point temperature
settings and high limit (ECO) activation. It is important that the entire back surface of the thermostat is in full contact or
flush with the tank. Improperly mounted thermostat will lead to improper heater operation.
1-½ Hex
Screw-in Flange
Terminal Block
Screw
Terminal Block
Zinc Incoloy Sheath
Element Rating Ink Stamped
on side of Terminal Block.
Direct Immersion “Screw-in” Type Heating Element
Page 4