Pilot Inspection, Testing, and Replacement (cont’d)
Step 6. Disconnect the pilot tube
using a 7/16” wrench and the main burner
feedline with a 3/4” wrench from the gas
control.
Step 7. Disconnect the spark igniter/flame sensor wire from
gas control.
Step 8. Remove the burner assembly from the combustion
chamber.
Step 9. Remove the pilot assembly from the main feedline
using a 1/4" nut driver.
Step 10. Visually inspect the spark igniter/flame sense wire for damage. Replace
the pilot assembly, if damage is found.
Step 11. With a multi-meter set to the ohms setting, check
continuity through the spark igniter/flame sense wire. Replace
the pilot, if there is no continuity.
Pilot Maintenance
Pilot and main
feedlines
Spark igniter/flame
sensor wire
Gas control
Burner assembly
Pilot assembly
1/4” nut driver
Multi-meter
20