Bradford-White Corp PDX-65S-65FB-3N Water Heater User Manual


 
NATURAL GAS AND LIQUID PROPANE GAS
Light Duty Energy Saver Models
M
eet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery Efficiency
M
odel
Number
A
pprox.
S
hipping
Weight
lbs.
G
F
loor to
Space
H
eating
S
upply
in.
A
F
loor to
Exhaust
O
utlet
in.
K
D
epth
in.
B
J
acket
Dia.
in.
C
apacity Recovery at
1
00°F Rise*
P
DX-50S-60FB-3N
PDX-65S-65FB-3N
PDX-75S-70FB-3N
U.S.
G
al.
4
8
65
75
Imp.
G
al.
4
0
54
62
Nat.
BTU/Hr.
I
nput
6
0,000
65,000
70,000
LP
BTU/Hr.
I
nput
6
0,000
60,000
65,000
Nat.
U.S.
G
PH
5
8
63
68
Nat.
Imp.
G
PH
4
8
52
57
LP
U.S.
G
PH
5
8
58
63
LP
Imp.
G
PH
4
8
48
52
6
8
71
1
/4
71
3
2
32
1
/8
36
3
03
330
375
2
2
22
26
5
2
1
/4
55
5
/8
54
1
/4
F
F
loor to
Space
H
eating
R
eturn
in.
1
5
3
/4
15
3
/4
19
5
9
3
/4
63
62
3
/4
J
F
loor
to
W
ater
C
onn.
in.
M
odel
Number
Approx.
S
hipping
Weight
kg.
G
F
loor to
Space
Heating
S
upply
mm.
A
F
loor to
Exhaust
Outlet
mm.
K
D
epth
mm.
B
J
acket
Dia.
mm.
Capacity Recovery at
5
6°C Rise*
PDX-50S-60FB-3N
PDX-65S-65FB-3N
PDX-75S-70FB-3N
Liters
182
246
284
Nat.
k
W
Input
17.6
19.0
21.0
LP
k
W
Input
17.6
17.6
19.0
LP
L
iters/
Hour
220
220
238
Nat.
L
iters/
Hour
220
238
257
1727
1809
1803
812
816
914
235
235
297
137
149
170
559
559
660
C
V
ent
Size
in.
3
3
3
C
V
ent
Size
mm.
76
76
76
1327
1489
1378
F
F
loor to
Space
Heating
R
eturn
mm.
400
400
483
E
F
loor
to
G
as
C
onn.
in.
1
3
5
/8
13
5
/8
16
1
/4
E
F
loor
to
Gas
C
onn.
mm.
346
346
413
H
F
loor to
Air
I
ntake
in.
6
7
69
1
/2
69
3
/8
H
F
loor to
Air
Intake
mm.
1701
1765
1762
L
C
t. Line
Distance
F
rom Intake
t
o Exhaust
in.
9
1
/4
9
1
/4
11
11
/16
L
C
t. Line
Distance
From Intake
t
o Exhaust
mm.
D
F
loor to
T&P
C
onn.
in.
5
2
1
/4
55
5
/8
54
1
/4
D
F
loor to
T&P
Conn.
mm.
1327
1489
1378
1517
1600
1594
J
F
loor
to
Water
C
onn.
mm.
Commercial Power Direct Vent Gas Water Heater
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm)
on 11" (203mm) centers. All gas connections ar
e 1/2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
All propane heaters are equipped with a cast iron burner. To order a propane heater change suffix “B” to “C” and “N” to “X”.
For 5 year model, change suffix “3” to “5”.
*Based on manufacturers rated recovery efficiency.
110 V.A.C Required for Power Venting / 110 V.A.C., 60HZ, 3.1 Amperes.
A
J
B
D & G
H
L
3
3
/8
"
E
F
C
K
Subtract 5ft. for each additional 90° elbow.
†Consult I&O Manual when using four or
more elbows.
3" Vent Pipe
PDX-50S
P
DX-65S
60 ft.
60 ft.
7
ft.
5
5 ft.
5
0 ft.
4
5 ft.
Max. Intake Length
Max. Exhaust Length
M
in. Vent Length
N
umber 1
of 2
9
0° Elbows† 3
4
" Vent Pipe
PDX-50S
P
DX-65S
100 ft.
100 ft.
7 ft.
95 ft.
90
ft.
85 ft.
P
DX-75S
5
0ft.
50ft.
7ft.
4
5ft
4
0ft
35ft.
P
DX-75S
90ft.
90ft.
7ft.
85ft.
80ft.
75ft.
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number 1
of 2
90° Elbows† 3
Printed in U.S.A.
755-B-0807-A
©2007, Bradford White Corporation. All rights reserved.
Ambler
, PA
For U.S. and Canada field ser
vice, contact your pr
ofessional installer or local Bradfor
d White sales r
epresentative.
Sales 800-523-2931
Fax 215-641-1670 / T
echnical Suppor
t
800-334-3393
Fax 269-795-1089
W
ar
ranty
800-531-2111
Fax 269-795-1089
International:
Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / T
echnical Suppor
t
866-690-0961 / 905-238-0100
Fax 905-238-0105 / www
.bradfor
dwhite.com
INTAKE/
COMBUSTION
AIR
RAIN CAP
VENT
EXHAUST
46
3
/4
"
Concentric Vent Terminal Kit
P/N 239-44069-01