Specifications
Thermal well TCO Limit Residential 188°F (87°C), Commercial 199°F (93°C)
Residential Temperature
Set Point Range
60°F (16°C) to 160°F (71°C) (Approximate temperatures)
Blower Temperature
Switch
Normally closed, opens @ 165°F (74°C), auto reset @ 130°F (54°C).
Blower 115VAC, 60Hz, 3.1 amps.
Pressure switch
Exhaust-Normally open, closes on vacuum increase @ -1.30.
Intake-Normally closed, opens on vacuum increase @ -1.15.
Power supply Dedicated 115VAC, 60 Hz, 15A
A
pproved Gas Type
N
atural or Propane. Unit must match gas type supplied.
Venting System Power vent through the wall or vertical through the roof
Approved Vent Materials PVC, CPVC or ABS
G
as Supply Pipe
M
inimum 1/2" NPT (schedule 40 black iron pipe recommended)
Minimum Clearance
for Servicing
18" from top, 24" from front, 4" sides and rear.
Water Supply Pressure 150 PSI maximum allowable working pressure. Check local codes for supply pressure
Gas Pressure 5.0" W.C. min. for Nat gas, 11.0" W.C. min. for L.P. gas, 14.0" W.C. maximum (Nat. & L.P.)
Commercial Temperature
Set Point Range
80°F (27°C) to 180°F (82°C) (Approximate temperatures)
Page 6
PDX Series
6