Bradford-White Corp MI30T Water Heater User Manual


 
23
Step 1. Rotate knob of combination thermostat gas valve to the off position.
Step 2. Remove outer jacket door.
Step 3. Remove inner door per SERVICE PROCEDURE RG-I, step 3a through 3e.
Step 4. Disconnect main burner feed line (¾ wrench), pilot tube (7/16 wrench)
and thermocouple (3/8) wrench from combination thermostat gas valve
and remove burner assembly from combustion chamber.
NOTE: Feedline nut for natural gas control uses right hand threads,
LP control uses left hand thread.
Step 5. Clean ScreenLok
®
Flame Arrestor using stiff brush, compressed air and/or shop vacuum to remove any scale
or other debris accumulation. Using a soft brush, clear jacket openings of any dirt, dust, restrictions or other
obstructions.
Step 6. Remove any debris from burner assembly per SERVICE PROCEDURE RG-V and reinstall burner assembly
into combustion chamber.
Step 7. Reconnect feedline, thermocouple and pilot tube to the combination thermostat/gas valve.
Step 8 Reinstall inner door per SERVICE PROCEDURE RG-I, steps 4 through 13.
Step 9. To resume operation follow the instructions located on the lighting instruction label or the lighting instruction
located in the installation and operation manual.
ScreenLok
®
Flame Arrestor Cleaning
For White Rodgers Control,
depress knob slightly and rotate
clockwise to the “OFF” position.
For Robertshaw Control, rotate
knob clockwise to the “OFF”
position.
Feedline