Bradford-White Corp ES-5500 Water Heater User Manual


 
EFT-18000-2-T-10 18.0 208y/120v 50.0 82 61 49 41 35 32 10 AWG
E
FT-24000-2-T-10 24.0 208y/120v 67.0 82 65 54 47 41 10 AWG
E
FT-18000-6-T-10 18.0 480y/277v 21.7 82 61 49 41 35 32 10 AWG
EFT-24000-6-T-10 24.0 480y/277v 28.9 82 65 54 47 41 10 AWG
E
FT-32000-6-T-10 32.0 480y/277v 38.5 — 87 73 62 55 8 AWG
M
odel
Number
k
W
Rating
Voltage AMPS
T
emperature Rise °F
1
.5
G
PM
2
.0
G
PM
2
.5
G
PM
3
.0
G
PM
4
.0
G
PM
3
.5
G
PM
R
ecommended
Wire Size
Thermostatic Triple Module Models (Three Phase)
Min Flow 0.7 GPM
M
ax Flow 4.0 GPM
Please specify your application
when you place your order.
Example:
EFT-24000-2-T-10-T2T
(Hot or Cold Water Feed)
Please specify your application when you place your order.
Example: EFT-32000-6-T-10-S (Sanitation 180°F).
Electric Instantaneous Water Heaters
Voltage Identification Code
For All Models
Voltage Code
Voltage
1
1 2 3 4 5 6 7 8
120 208 220 240 277 480 380 415
Example: ES-5500-4-S-10-S
The 4 in the model number indicates 240 volt.
Please be advised that the voltages listed in the V
oltage Identification Code
may not be available for all models.
Additional voltages and wattages are available. For more information please
consult factory.
5
Electrical Configurations and Requirements for Bradford White Three Phase Tankless Water Heaters.
All Bradford White three-phase units are custom made to order and as such are, non-returnable and non-refundable. We urge you therfore to check your
electrical supply, making sure all criteria for operating your Bradford White water heaters are met, especially that a neutral line is available for all 480/277 volt units.
F
Bradford White 208/120 Three Phase Units
Delta Configuration
Requires: 3 Lives, 1 Ground (earth)
Three-Phase delta; Three-wire
Bradford White 480/277 Three Phase Units
Star Configuration
Requires: 3 Lives, 1 Neutral and
1 Ground
Three-Phase star; Four-wire; non-earthed neutral
F
L1
L2
L3
2
L1
N
L2
L3
Please consult local codes for electrical requirements.
Additional voltages and wattages are available. For more
information please consult factory.
Refer to Voltage Identification Code Chart
and wiring diagram on page 5.
Multi-Outlet Three Phase Applications: Modular Hand
Washing, Multi-Shower, Restaurants, Beauty Salons.
Specifications:
Dimensions:
15
1
4"x 12
1
4"x 4
1
4"
Weight: 15 lbs.
Materials:
Cover: Enameled Steel.
Glass reinforced “UDEL†” Heater
Body and Ni Chrome Element
Color: White
Element: Triple replaceable
cartridge inserts
Pipe-Fittings: 1/2" compression
at bottom of unit.
Operating Pressure: Min 25 PSI,
Max 150 PSI.
SPEC OPTIONS:
S = Sanitation 180°F
ML = Multi-Lav temp
setting 105 to
110 - 0.5 turn on up
to 8 lavs
T2T = Hot or Cold feed staged
turn-on, max 4.0GPM
FS = Factory Set
(ambient to 180°F)
ELECTRICAL
S
UPPLY
4
1
4
"
1
5
1
4
"
12
1
4
"
7
1
4
"
OUTLETINTLET