Bradford-White Corp Electric Instantaneous Water Heaters Water Heater User Manual


 
E
FC-5500-4-S-10 5.5 240 23.0 75 50 38 25 18 10 AWG
EFC-6500-4-S-10 6.5 240 27.0 88 59 44 30 22 10 AWG
EFC-7500-4-S-10 7.5 240 32.0 — 68 51 34 25 8 AWG
EFC-9500-4-S-10 9.5 240 40.0 — 86 65 43 32 8 AWG
EFC-8300-2-S-10 8.3 208 39.0 — 76 57 38 29 8 AWG
Model
N
umber
kW
R
ating
V
oltage AMPS
Temperature Rise °F
0.5
GPM
0.75
GPM
1.0
GPM
1.5
GPM
2.0
GPM
Recommended
W
ire Size
Flow Controlled (Single Phase)
Turn on 0.5 GPM (up to 6.5kW)
T
urn on 0.7 GPM (7.5 kW and up)
M
ax Flow 2.0 GPM
5
1
4
"
1
1
2
"
3
4
"
2
7
8
"
10
3
4
"
9
3
4
"
OUTLET INTLET
Electric Instantaneous Water Heaters
Specifications:
Dimensions: 10
3
4" x 5
1
4" x 2
7
8"
Weight: 3 lbs.
Materials:
Cover: ABS UL rated 94Vo.
Glass reinforced “UDEL†” Heater Body
and Ni Chrome Element
Color: White
Standard temperature range
100°F-140°F.
Maintains accurate temperature control
±
1°F
Element: Replaceable cartridge insert
Pipe-Fittings: 1/2" NPT compression at
bottom of unit.
Operating Pressure: Min 25 PSI,
Max 150 PSI.
The unit must have 2 independent electrical circuits using correctly rated wire
and 2 circuit breakers.
Specifications:
Dimensions: 10" x 9" x 3"
W
eight: 8 lbs.
Materials:
Cover: Enameled Steel.
Glass r
einforced “UDEL†” Heater
Body and Ni Chr
ome Element
Color: White
Element: Dual replaceable
cartridge inserts
Pipe-Fittings: 3/4" NPT pipe
fittings at the bottom of the unit.
Operating Pressure: Min 25 PSI,
Max 150 PSI.
EFT-19000-4-D-10 19.0 240 80 (2 x 40 Amps) 87 65 52 43 8 AWG per module
Model
Number
kW
Rating
Voltage AMPS
Temperature Rise °F
1.5
GPM
2.0
GPM
2.5
GPM
3.0
GPM
Recommended
Wire Size
Series Two - Thermostatic (Single Phase)
(Twin Module) With Single Thermostatic Control
Activated in stages based on demand
Min. flow 0.7 GPM Max Flow 3.0 GPM
Please consult local codes for electrical requirements. Additional
voltages and wattages are available. For more information please
consult factory.
Refer to Voltage Identification Code Chart on page 5.
Applications: Single Phase Only.
Kitchen Sinks, Bar Sinks, Dual Lavs, Utility Sinks, Manufacturing
Facilities, and Modular Buildings.
Please consult local codes for electrical requirements.
Additional voltages and wattages are available. For
more information please consult factory.
Refer to Voltage Identification Code Chart
on page 5.
Applications: Single Phase Only.
Residential-Single Shower (Cabin or Condo), Multi Lavs.
SPEC OPTIONS:
Multi Lavs = ML 0.5 turn on
set temp.
Set Temp = 105°F.
9
"
10
"
3
"
ELECTRICAL
SUPPLY
4
"
3