GENERAL INFORMATION
Full Load Amperes-(Phase 1/Phase 3)
Page 4
Input Kw 208V
28.8/16.6
240V 277V 380V 415V 480V
6
9
12
13.5
15
18
43.2/25
57.6/33.3
64.9/37.5
72.1/37.5
86.5/50
25/14.4
37.5/21.6
50/28.9
56.2/32.5
62.5/36.1
75/43.4
21.6
32.4
43.3
48.7
54.1
64
10
14
19
21
23
28
8.3
12.5
16.7
18.8
20.9
25
12.5/7.2
18.7/10.8
25/14.4
28.1/16.2
31.2/18
37.5/21.6
Surface Mounted Thermostats
E32 series medium duty commercial water heaters use only surface mounted thermostats. Surface mounted
thermostats are mounted into a bracket which holds the thermostat against the side of the tank. Surface mounted
thermostats respond to tank surface temperatures to sense a call for heat, set point temperature settings and high limit
(ECO) activation. It is import that the entire back surface of the thermostat is in full contact or flush with the tank. An
improperly mounted thermostat will lead to improper heater operation.
Manual
ECO (high limit)
Reset button
Temperature
control Dial
Surface Mount
Combination Thermostat/
ECO (high limit)
89T Series
1-½ Hex
Screw-in Flange
Terminal Block
Screw
Terminal Block
Zinc Plated Copper or
Incoloy Sheath
Element Rating Ink Stamped
on side of Terminal Block.
Direct Immersion “Screw-in” Type Heating Element
0642
4500W 240V
RC02404524