Commercial Atmospheric Vent Gas Water Heater
N
ATURAL GAS AND LIQUID PROPANE GAS
Light Duty Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
8
0% Thermal Efficiency
Model
N
umber
Approx.
Shipping
W
eight
l
bs.
G
Floor to
S
pace
Htg.
Outlet
i
n.
A
Floor to
F
lue
Conn.
i
n.
H
Floor to
W
ater
Conn.
i
n.
B
Jacket
D
ia.
i
n.
Capacity Recovery at
100°F Rise*
50T-65FB-3N
6
5T-65FB-3N
U.S.
Gal.
Imp.
Gal.
N
at.
BTU/Hr.
Input
65,000
6
5,000
N
at.
U.S.
GPH
N
at.
Imp.
GPH
59
1
/
4
6
3
57
6
0
3
/
4
164
2
05
22
2
4
50
5
3
1
/
2
E
Floor to
G
as
Conn.
i
n.
13
1
2
3
/
1
6
13
1
/
2
1
3
1
/
2
F
Floor to
S
pace
Htg.
Return
i
n.
63
6
3
53
5
3
L
P
U.S.
GPH
L
P
Imp.
GPH
59
6
1
49
5
1
48
6
5
40
5
4
D
Floor to
T
&P
Conn.
i
n.
50
5
3
1
/
2
C
Vent
S
ize
i
n.
4
4
Model
Number
A
pprox.
Shipping
Weight
kg.
G
Floor to
Space
H
tg.
Outlet
mm.
A
Floor to
Flue
C
onn.
mm.
H
Floor to
Water
C
onn.
mm.
B
Jacket
Dia.
mm.
C
apacity Recovery at
56°C Rise*
5
0T-65FB-3N
6
5T-65FB-3N
Liters
N
at.
kW
Input
1
9.1
1
9.1
L
P
BTU/Hr.
Input
61,000
6
3,000
L
P
kW
Input
1
7.9
1
8.4
1
82
2
46
N
at.
Liters/
Hour
1
550
1
600
1
448
1
543
K
Depth
i
n.
26
2
8
K
Depth
mm.
6
60
7
11
7
4
9
3
5
59
6
09
1
270
1
359
E
Floor to
Gas
C
onn.
mm.
3
30
3
09
3
43
3
42
F
Floor to
Space
H
tg.
Return
mm.
2
38
2
38
L
P
Liters/
Hour
2
23
2
31
D
Floor to
T&P
C
onn.
mm.
1
270
1
359
C
Vent
Size
mm.
1
02
1
02
K
K
E
C
B
AHH
D&G
F
B
**
E
F
A
TOP VIEW
T
C
A
D&G
** 75T=11"
** 100T=16"
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "B" to "S" and "N" to"X".
For 5 year models, change suffix “3” to “5”.
*Based on manufacturers rated recovery efficiency.
NSF kits available.
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3⁄4" NPT
(19mm) on 8" (203mm) centers. All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA),ANSI standard Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
Printed in U.S.A.
700-B 1008
©2008, Bradford White Corporation. All rights reserved.
Ambler
, PA
For U.S. and Canada field ser
vice, contact your pr
ofessional installer or local Bradfor
d White sales r
epresentative.
Sales 800-523-2931
●
Fax 215-641-1670 / T
echnical Suppor
t
800-334-3393
●
Fax 269-795-1089
●
W
ar
ranty
800-531-2111
●
Fax 269-795-1089
International:
Telephone 215-641-9400
●
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / T
echnical Suppor
t
866-690-0961 / 905-238-0100
●
Fax 905-238-0105 / www
.bradfor
dwhite.com