Bradford-White Corp CombiCor TTW Water Heater User Manual


 
553-B-0904-A Printed in U.S.A.
PR ODUCTS ONLY FOR PR OFESSIONALS
M2-C-TW50T10BN M2-C-TW75T10CN
Input 65,000 BTU/H 19.0KW 75,000 BTU/H 22.0KW
Water Heating
CA
EF
.65 .64
Thermal Efficiency 80 80
First Hour Rating
83 100 379 112 140 511
Imp.Gal. Gal. Liters Imp.Gal. Gal. Liters
Rec. Rate 90°F Rise 58 70 261 67 80 306
and 50°C Rise Imp.GPH GPH Liters/H Imp.Gal. GPH Liters/H
Space Heating
CA
AFUE
%
82.0 82.0
Max. Heating
52,000 BTU/H 15.2KW 60,000 BTU/H 17.6KW
Capacity
Vitraglas,
®
CombiCor
®
and UltraCoil
®
are registered trademarks of Bradford White
®
Corporation.
©2004, Bradford White Corporation. All rights reserved.
Through-The-Wall Gas Water Heater
A
B
3"
PVC
VENT - C
11 3/8"
D
E
F
G
(provided with heater)
VENT CONNECTOR
3" PVC
VENT TERMINAL
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and
150 PSI working pressure (1034 kPa). All potable water and heat exchanger
connections are
3
4
" NPT (19mm), all gas connections
1
2
" (13mm). All models
design certified by CSA International (formerly AGA/CGA) and peak
performance rated.
Dimensions and specifications subject to change without notice in
accordance with our policy of continuous product improvement.
6-Year Limited Warranty on
Component Parts
BRADFORD WHITE CORPORATION
has a 6-year warranty on replaceable
parts – gas valve, thermostat, burner,
dip tube, drain valve and blower
assembly. These quality components
are manufactured for us by industry
leaders and will be replaced in the
event of failure during the parts
warranty period (exclusive of shipping
and re-installation cost.)§
10-Year Limited Heat Exchanger
and Tank Warranties
BRADFORD WHITE CORPORATION
LIMITED WARRANTY: Protects your
investment in a quality glass-lined
heater. If the tank or heat exchanger
leaks for reasons of faulty materials,
workmanship, or corrosion within the
warranty period, the heater will be
replaced with a comparable heater of
our manufacture (exclusive of shipping
and re-installation cost.)§
§ Some states do not allow limitations on warranties. See complete copy of the
warranty included with the heater. Indicated warranties apply to USA, Canada, and
Puerto Rico installations.
*Based on manufacturers rated recovery efficiency.
All propane gas water heaters are equipped with cast iron
burner. Change suffix “BN” or “CN” to “CX”.
110 V.A.C. Required for Power Venting
110 V.A.C. 60HRZ 2.1 Amperes
LP Propane Gas Inputs Recovery at 50°C Rise and 90°F Rise
Imp GPH US GPH Liters/Hr
M-2-C-TW50T10CX 18.4 KW 63,000 BTU/Hr 56 67 254
M-2-C-TW75T10CX 21.4 KW 73,000 BTU/Hr 65 79 295
Sales/800-523-2931
Fax/215-641-1670
Technical Support/800-334-3393
Fax/269-795-1089
Warranty/800-531-2111
Fax/269-795-1089
International:
Telephone/215-641-9400
Telefax/215-641-9750
Ambler, PA
888-538-7833
Fax on Demand:
bradfordwhite.comwww.
For U.S. and Canada field service,
contact your professional installer or
local Bradford White sales representative.
Sales/Technical Support
866-690-0961
905-238-0100
Fax/905-238-0105
Mississauga, ON
www.bradfordwhitecanada.com
MAXIMUM HORIZONTAL AND VERTICAL VENT
3" PVC, ABS &
CPVC (76mm) 4" PVC, ABS & CPVC (102mm)
30 ft. (9.1 m) 60 ft. (18 m)
(3) 90° elbows
Note: 90° elbow is equivalent to 5ft. (1.5m)
Deluxe Energy Saver Models
66
7
8 1699 22 559 3 76 48
7
8 1243 16
5
8 422 30
5
8 778 56 1422 197 89
71
5
8 1820 26 660 3 76 53 1346 19 483 29
3
8 746 61 1549 286 130
Meet or exceed ASHRAE 90.1b (Current Standard). Meets C.E.C. Requirements.
Imp. U.S.
Model Gal. Gal. BTU KW Imp. U.S. Liters/
Number Cap. Cap. Liters Input BTU GPH GPH Hr
M-2-C-TW-50T10BN(LP) 39 47 178 65,000 19.0 57 69 261
M-2-C-TW-75T10CN(LP) 61 73 276 75,000 22.0 67 80 303
NATURAL GAS
Recovery
50°C. Rise/
90°F. Rise*
ABCDEFG
Fl. to
H.W.
Fl. to Fl. to Fl. to Fl. to Outlet & Approx.
Flue Jacket Vent T&P Gas CW H.E. Shipping
Conn. Dia. Size Conn. Conn. Inlet Conn. Weight
In. In. In. In. In. In. In. lbs.
mm mm mm mm mm mm mm kg
Based on ANSI Z21.10.1 and 10.3 and DOE Test Methods.
Based on ANSI/ASHRAE 124 Standard.
Actual values may vary based on circulator flow rate, number of zones, water and
space heating demands. Numbers subject to change.