Bradford-White Corp 65T Water Heater User Manual


 
Commercial Atmospheric Vent Gas Water Heater
N
ATURAL GAS AND LIQUID PROPANE GAS
Light Duty Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
8
0% Thermal Efficiency
Model
Number
A
pprox.
Shipping
Weight
lbs.
G
Floor to
Space
H
tg.
Outlet
in.
A
Floor to
Flue
C
onn.
in.
H
Floor to
Water
C
onn.
in.
B
Jacket
Dia.
in.
C
apacity Recovery at
100°F Rise*
50T-65FB-3N
6
5T-65FB-3N
7
5T-80B-3N
100T-88B-3N
U
.S.
Gal.
I
mp.
Gal.
Nat.
B
TU/Hr.
Input
65,000
6
5,000
7
6,000
85,000
Nat.
U
.S.
GPH
Nat.
I
mp.
GPH
59
1
/4
6
3
6
3
3
/4
68
5
/8
57
6
0
3
/4
6
1
1
/4
67
5
/8
164
2
05
2
94
420
22
2
4
2
6
28
1
/4
50
5
3
1
/2
5
3
50
5
/8
E
Floor to
Gas
C
onn.
in.
13
1
2
3
/1
6
1
6
1
/2
15
5
/8
13
1
/2
1
3
1
/2
1
7
3
/4
17
5
/8
F
Floor to
Space
H
tg.
Return
in.
63
6
3
7
4
82
53
5
3
6
2
69
LP
U
.S.
GPH
LP
I
mp.
GPH
59
6
1
7
4
85
49
5
1
6
2
71
48
6
5
7
5
100
40
5
4
6
2
83
D
Floor to
T&P
C
onn.
in.
50
5
3
1
/2
5
3
59
5
/1
6
C
Vent
Size
in.
4
4
4
4
Model
Number
A
pprox.
Shipping
Weight
kg.
G
Floor to
Space
H
tg.
Outlet
mm.
A
Floor to
Flue
C
onn.
mm.
H
Floor to
Water
C
onn.
mm.
B
Jacket
Dia.
mm.
C
apacity Recovery at
56°C Rise*
5
0T-65FB-3N
6
5T-65FB-3N
7
5T-80B-3N
1
00T-88B-3N
L
iters
Nat.
kW
I
nput
1
9.1
1
9.1
2
2.2
2
5.0
LP
B
TU/Hr.
Input
61,000
6
3,000
7
6,000
88,000
LP
kW
I
nput
1
7.9
1
8.4
2
2.2
2
5.8
1
82
2
46
2
84
2
79
Nat.
Liters/
H
our
1
550
1
600
1
619
1
743
1
448
1
543
1
556
1
718
K
Depth
in.
26
2
8
3
0
32
1
/4
K
Depth
mm.
6
60
7
11
7
62
8
19
7
4
9
3
1
33
1
91
5
59
6
09
6
60
7
18
1
270
1
359
1
346
1
286
E
Floor to
Gas
C
onn.
mm.
3
30
3
09
4
19
3
97
3
43
3
42
4
51
4
48
F
Floor to
Space
H
tg.
Return
mm.
2
38
2
38
2
80
3
10
LP
Liters/
H
our
2
23
2
31
2
80
3
22
D
Floor to
T&P
C
onn.
mm.
1
270
1
359
1
346
1
506
C
Vent
Size
mm.
1
02
1
02
1
02
1
02
K K
E
C
B
AHH
D&G
F
8"
B
**
E
F
TOP VIEWTOP VIEW
T
C
A
D&G
** 75T=11"
** 100T=16"
All propane heaters are equipped with a cast iron burner. To order a propane heater remove the “B” designator and change suffix “N” to “X”.
For 5 year models, change suffix “3” to “5”.
*Based on manufacturers rated recovery efficiency.
Hand Hole Cleanout standard on 100T and optional on 75T models.
NSF kits available.
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). The 50T and 65T water connections are
3⁄4" NPT (19mm) on 8" (203mm) centers. The 75T water connections are 1" (25mm) NPT on 11" (279mm) centers and 100T water connections are 1
1
4"
(32mm) NPT on 16" (406mm) centers. All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA),ANSI standard Z-21.10.1 and/or 10.3 and peak performance rated. This Water Heater
can be used as an Automatic Storage Heater, and an Automatic Circulating Tank Heater.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
T
oxic chemicals, such as those used for boiler tr
eatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
Printed in U.S.A.
700-B 0807
©2007, Bradford White Corporation. All rights reserved.
Ambler
, PA
For U.S. and Canada field ser
vice, contact your pr
ofessional installer or local Bradfor
d White sales r
epresentative.
Sales 800-523-2931
Fax 215-641-1670 / T
echnical Suppor
t
800-334-3393
Fax 269-795-1089
W
ar
ranty
800-531-2111
Fax 269-795-1089
International:
Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / T
echnical Suppor
t
866-690-0961 / 905-238-0100
Fax 905-238-0105 / www
.bradfor
dwhite.com
75T AND 100T MODELS
50T AND 65T MODELS