Bradford-White Corp 238-48248-00 Water Heater User Manual


 
2
Minimum Clearances
(Replaces pg. 9 in instruction manual.)
WARNING
Failure to adhere to these installation and operating instructions may create a hazard to
life and property and will nullify the warranty.
This installation must allow access to the front of the water heater and adequate
clearance must be provided for servicing and operating this water heater. The water
heater may be installed on either a combustible or non-combustible floor. If the water
heater is to be installed directly on carpeting, it must be installed on top of a metal or
wood panel (or equivalent) extending beyond the full width and depth of the water
heater by at least 3 in. (7.6 cm) in any direction or, if the appliance is to be installed in
an alcove or closet, the entire floor must be covered by the panel. If the rating plate or
the label on the front of the heater specifies minimum clearances less than those listed
in the below table, the water heater must be installed in accordance with the minimum
clearances listed on the rating plate or the label on the front of the heater.
If it is necessary to install this water heater in an alcove, use the clearances listed in
Figure 1.
Figure 1. Minimum Clearances for an Alcove Installation.