Bradford-White Corp 238-44219-00 Water Heater User Manual


 
4
THERMOSTAT ADJUSTMENT
(Replaces pg. 19 in instruction manual.)
status
160°F and 180°F control
Figure 2
The gas control knob is set to the “OFF” position when shipped from the
factory. Remember that lower temperature settings are more energy
efficient. Adjust the temperature by turning the gas control knob. It is
suggested that the starting point setting not exceed approximately 120°F
(48.9°C) or “Hot” setting on the thermostat.
DANGER
Hotter water increases the risk of scald injury. Scalding may occur within five
(5) seconds at a temperature setting of 140F (60
C). To protect against hot
water injury, install an ASSE approved mixing valve in the water system.
This valve will reduce point of discharge temperature by mixing cold and hot
water in branch water lines. A licensed plumbing professional or local
plumbing authority should be consulted.
Note: This water heater is equipped with an energy cut out device to
prevent overheating. Should overheating occur or the gas supply fail to
shut off, turn off the manual gas control valve to the appliance and call a
qualified service technician.
Note: Whenever the water heater is filled with cold water, condensate will
form on the cool tank surface and drops of water will fall on the hot burner
and combustion chamber surfaces producing a “sizzling” noise.
Condensation is normal and does not indicate a leak. It will disappear
when the tank becomes heated.