Bosch Appliances W125K... Water Heater User Manual


 
6
OPERATING INSTRUCTIONS
WARNING
If the water heater has been damaged or exposed to flood-
ing, fire, or sooting do not operate the heater until all cor-
rective steps have been taken by a qualified serviceman.
FILLING
Before proceeding with operation of the water heater make
sure that the system is filled with water.
- Turn the water flow selector handle clockwise ( )
against stop.
- Open all hot water faucets connected to the W125K…to
allow trapped air to escape from heater and piping.
- Close all faucets, once water flows freely and all air
has escaped from system.
- The water heater is now ready to be lit.
SERVICE HINT
The screen (strainer) in the water valve, located in inlet of
the water valve, may require occasional cleaning due the
foreign material in the water supply. This will restrict the
flow of water and may affect heater operation and prolong
filling time. To inspect the screen, close the cold water sup-
ply valve ahead of the heater, disconnected cold water line
from inlet of water valve and remove screen from inlet. Clean
if required, replace screen in inlet to water valve, recon-
nected and open cold water supply valve.
LIGHTING
Light the water heater in accordance with the instructions
on the Lighting and Operating Plate on the water heater.
For your convenience, the instructions are repeated below.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information, (first section) of the
Lighting Instruction Plate on the cover.
2. The main manual gas valve must be closed (turn valve
handle clockwise , see fig. below ) and the gas
valve button slide to the far left under the OFF
mark.
3. Wait five (5) minutes to clear out any gas. If you smell
gas, stop! Follow ‘’B’’ in the safety information above on
this label. If you don’t smell gas, go to next step.
4. The pilot burner is located behind the peephole located
in the front center of the jacket directly below this
instruction plate.
5. Slide the gas valve button to right to pilot position ( )
and open main manual gas valve (by turning valve handle
counterclockwise ).
6. Fully depress gas valve button ( ) and light pilot by
pushing pilot igniter button ( )
7. Observe pilot flame through peephole. The gas valve
button should be held down at least 10 seconds with
pilot burning. When the gas valve button is released the
pilot should continue to born.
- If the gas valve button does not pop up when released
stop and immediately call your service technician or gas
supplier.
- If the pilot will not stay lit after several tries, slide the gas
valve button to the left. Under the OFF ( ) mark, turn
the manual gas valve to the off position and call your
service technician or gas supplier.
8. Slide gas valve button to the right to the ON position
( ) the heater will now fire when water is drawn at
a rate greater than the threshold flow rate (see manual).
Note: If main burner should fait to ignite make sure pilot is
burning. If not repeat lighting procedure steps 1 through 8.