Bosch Appliances D720 Smoke Alarm User Manual


 
10
Turn the Entire System On With Delays
I have this feature.
I do not have this feature.
This feature requires a passcode.
Command 1 is used to arm the entire system, both perimeter and interior points.
Once you enter Command1, the exit delay time starts. You now have a
predetermined amount of time to exit the protected area before the system arms.
During the exit period, you can move through motion detectors or any protected area
on your way to any exit without causing an alarm. To cancel Command 1, enter
your personal passcode and press [ENT].
Note: If you leave the building after the exit time expires, you can begin the entry
delay or initiate an alarm. It this happens, disarm your system by entering
your personal passcode and press [ENT]. It your system reports to a central
station, call them if an alarm occurs.
Application
Command1 is useful in applications where you want your cleaning or service
personnel, or anyone else to arm your system when they leave, but you do not
want them to have the passcode to disarm the system. Command 1 arms the
system, but does not disarm the system.
COMMAND 1
Arming with COMMAND 1:
1. Ensure all points are secure. All of the Point Status indicator
lights on the Keypad should be off. If not, refer to Force Arming
the System on page 29.
2. Press the [COMMAND] bar. The Command mode indicator light
comes on.
3. Press the [1] key. The PERIMETER indicator and the INTERIOR
indicator lights begin to flash on and off, showing the system has
begun exit delay time.
4. To disarm your security system or cancel COMMAND 1, enter your
personal passcode and press [ENT] before the delay time expires.