Blue Rhino 70000 Electric Heater User Manual


 
Cleaning emitter and burner. Series 6000-93000 LP Gas 405121 12
®
For assistance call 1.800.762.1142.
Cleaning emitter and burner. Series 6000-93000 LP Gas 405121 13
®
For assistance call 1.800.762.1142.
X
X
X
X
X
Burner Connections
1. Make sure the regulator valve and hose connections are securely fastened to the burner and the
tank.
2. If your unit was assembled for you, visually check the connection between the burner pipe and
orice. Make sure the burner pipe ts over the orice.
WARNING: Failure to inspect this connection or follow these instructions could cause a re
or an explosion which can cause death, serious bodily injury, or damage to property.
3. Please refer to diagram for proper installation.
4. If the burner pipe does not rest ush to the orice, please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.
2. Make sure control knobs are off.
3. Turn LP gas tank ON at valve.
4. Spoon leak check solution at all “x” and arrow locations.
5. If any bubbles appear turn LP gas tank OFF, reconnect and re-test. If you continue to see bubbles after several attempts,
disconnect LP gas source and contact 1.800.762.1142 for assistance.
6. If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.