Black & Decker MUZ-FD09NA Air Conditioner User Manual


 
44
3
SPECIFICATION
Outdoor unit model MUZ-FD09NA MUZ-FD12NA
Capacity
Rated (Minimum~Maximum)
Cooling 1
Btu/h 9,000 (2,800~9,000) 12,000 (2,800~12,000)
Heating 47 1
Btu/h 10,900 (3,000~18,000) 13,600 (3,000~21,000)
Capacity Rated
Heating 17 2
Btu/h 7,700 8,300
Power consumption
Rated (Minimum~Maximum)
Cooling 1
W
650 (160~650) 960 (160~960)
Heating 47 1
W
750 (150~2,400)
980
(150~2,400)
Power consumption Rated
Heating 17 2
W 1,730 1,780
EER
1
[SEER]
3 Cooling 13.8 [23.0] 12.5 [22.0]
HSPF IV(V)
4 Heating 10.55 (7.4) 10.55 (7.4)
COP Heating
1 4.30 4.10
External nish Munsell 3Y 7.8/1.1
Power supply V , phase , Hz 208/230 , 1 , 60
Max. fuse size (time delay) A 15
Min. circuit ampacity A 12
Fan motor F.L.A 0.56
Compressor
Model SNB130FQAH
R.L.A 8.6
L.R.A 10.8
Refrigerant control Liner expansion valve
Sound level
1
Cooling dB(A) 48 48
Heating dB(A) 49 49
Defrost method Reverse cycle
Dimensions
W in. 31-1/2
D in. 11-1/4
H in. 21-5/8
Weight Ib. 80
Remote controller Wireless type
Control voltage
(by built-in transformer)
VDC 12 - 24
Refrigerant piping Not supplied
Refrigerant pipe size
(Min. wall thickness)
Liquid in. 1/4 (0.0315)
Gas in. 3/8 (0.0315)
Connection method
Indoor Flared
Outdoor Flared
Between the indoor &
outdoor units
Height differ-
ence
ft. 40
Piping length ft. 65
Refrigerant charge (R410A) 2 lb. 9 oz.
Refrigeration oil (Model) NE022
NOTE : Test conditions are based on ARI 210/240.
1 : Rating conditions (Cooling) — Indoor : 80 FDB, 67 FWB, Outdoor : 95 FDB, (75 FWB) Rated frequency
(Heating) — Indoor : 70 FDB, 60 FWB, Outdoor : 47 FDB, 43 FWB Rated frequency
2 : (Heating) — Indoor : 70 FDB, 60 FWB, Outdoor : 17 FDB, 15 FWB Maximum frequency