Bissell 89Q9 Vacuum Cleaner User Manual


 
WARNING:
To reduce the risk of electric
shock, turn Power Switch OFF
and disconnect polarized plug
from electrical outlet before
performing maintenance or
troubleshooting checks.
Maintenance and care
Replace light bulb
1. Unplug cleaner from electrical outlet.
2. Remove detachable canister and recline
handle of vacuum.
3. Using a screwdriver, remove the one screw
as shown and lift off the lens.
4. Remove the bulb from the socket by grasping
bulb and pulling straight out. Install the new
bulb by pushing it gently into the socket until
the bulb snaps into place.
5. Reposition lens and secure with the one
screw.
TurboBrush maintenance
The TurboBrush should be checked regu-
larly for clogs or debris wrapping around
the brush roll.
1. Unplug vacuum from electrical outlet.
2. If a clog is present or debris is visible, unscrew
the two screws on the back of the TurboBrush to
remove the faceplate and clear any obstructions.
3. To clean debris from the brush roll, remove the
screw located on the belt cover. Lift the belt
cover. Remove the brush roll from the drive belt
and clean debris.
4. Reposition the drive belt on the brush roll. Place
ends of brush roll in slots on sides as shown.
Reposition belt cover and secure with shorter
screw. Reposition faceplate and secure with two
longer screws.