9
Use only BISSELL Replacement Filters in your BISSELL Cleanview.
Upper Tank Filter 203-1085
Unplug the cleaner from electrical outlet.
The Upper Tank Filter can be reached by removing the
Dirt Container, reaching underneath the Upper Tank and
turning the rim of the Filter Frame to unlock. Pull straight
down to remove. Brush the dirt off the Louvers and
Upper Tank Filter.
The foam Upper Tank Filter may be removed and hand
washed in cold water with mild detergent. Rinse well
then air dry thoroughly before replacing.
The Upper Tank and Louvers may also be wiped clean
with a damp cloth.
Note: For easier access, the entire Upper Tank
may be removed by turning the knob on the
back of the cleaner to unlock and pulling the
entire tank straight out.
Use only BISSELL Replacement Filters in your BISSELL CleanView.
Pre-Motor Filter 203-1073
Post-Motor Filter 203-1009
HEPA Media Post-Motor Filter 32076 (Select Models Only)
Unplug the cleaner from electrical outlet.
The Pre-Motor Filter protects the motor from dirt particles.
It is located in the slide out tray underneath the Dirt
Container. If the filter becomes dirty, pull out the tray, lift
out the filter and clean.
The Post-Motor Filter assists in the filtration process to
return clean air to the room. It is located behind the door
on the side of the cleaner. If the filter becomes dirty,
open the door, remove the filter and clean.
Note: Select Models come with a white, pleated
HEPA Media Filter. This filter is not washable and
must be replaced.
The standard filters may be hand washed in cold water
with mild detergent. Rinse well and air dry thoroughly
before replacing.
Cleaning The Upper Tank & Filter
1.
2.
3.
WARNING:
Do Not operate cleaner
with damp or wet
filters or without all
filters in place.
Cleaning The Pre-Motor and Post-Motor Filters
1.
2.
3.
4.
WARNING:
To reduce the risk of injury
from moving parts, turn
off vacuum cleaner and
disconnect Power Plug
from electrical outlet.
Post-Motor
Filter
Pre-Motor
Filter
4.