Use only BISSELL Replacement Filters in your BISSELL vacuum.
Filter Kit (#203-1089)
Style 7 Post-Motor Filter Set 2 pack (#3099)
Style 7 HEPA Post-Motor Filter (#32076)
Unplug vacuum from electrical outlet.
The Pre-Motor Filter, located in the bottom of the bag compartment, protects the motor
from dirt particles. If filter becomes dirty, lift out filter and clean.
The Post-Motor Filter assists in the filtration process to return clean air to the room. To
remove this filter, open the door on the side of the cleaner. Grasp filter and pull it straight out.
Note: Select Models come with a white, pleated HEPA Media Filter.
This filter is not washable and must be replaced.
The filters may be hand washed in cold water with mild detergent, then air dried.
Reposition filters when completely dry.
You should check your vacuum cleaner’s Rotating Floor Brush and Drive Belt regularly
for wear or damage. You should also clean the brush and brush ends of string, hair, and
carpet fibers. These can wrap around the brush and hamper its ability to effectively
clean your carpet. Also remove any debris that has accumulated under the brush cover.
Unplug vacuum from electrical outlet.
Place handle in Low position and turn vacuum over so bottom side is up.
Remove the five screws as shown with a screwdriver. Lift the Brush Cover off.
Grasp Rotating Floor Brush at both ends and lift.
Clean strings, hair and other debris from Rotating Floor Brush,
paying particular attention to brush ends.
Clean strings, hair and other debris from Motor Pulley and Drive Belt areas.
Check Drive Belt carefully for wear, cuts or stressed areas. Replace if worn.
Check Air Passageway for obstructions. Remove debris from this area.
Use only BISSELL Style 7 Replacement Belts (#32074) in your
BISSELL vacuum.
Unplug cleaner from electrical outlet.
With Rotating Floor Brush removed from vacuum cleaner (Steps 1-4 of
Check Rotating Floor Brush and Drive Belt), grasp old Drive Belt and remove
from Motor Pulley. Discard old Drive Belt.
Place new Drive Belt over Motor Pulley and stretch other end over Rotating
Floor Brush in the space between the bristles.
Place ends of Rotating Floor Brush down into slots on sides as shown.
Turn Rotating Floor Brush by hand several times in direction of Motor Pulley. If properly
installed, Drive Belt will center itself.
Reposition Brush Cover and five screws. Tighten screws securely. Make sure end of
Brush Cover is snapped into place.
Cleaning Pre-Motor & Post-Motor Filters
Check Rotating Floor Brush and Drive Belt
WARNING:
To reduce the risk of
injury from moving parts,
turn off vacuum and
disconnect Power Plug
from electrical outlet.
3.
4.
5.
3.
4.
5.
1.
2.
6.
7.
8.
Post-Motor
Filter
Pre-Motor
Filter
Motor
Pulley
Air
Passageway
1.
2.
WARNING:
Do not operate cleaner
with damp or wet filters or
without all filters in place.
Replace Drive Belt
8
3.
4.
5.
1.
2.
6.
Brush
Cover