Bissell 1692 Vacuum Cleaner User Manual


 
Reduced Spray Or No Spray.
Possible Causes Remedies
Bladder may be empty. Turn power OFF; refill tank with
hot tap water.
The Lint Screen may be clogged. Clean out Lint screen page 7.
Tank-in-Tank may not be seated properly. Turn power OFF; remove tank and
reseat tank.
Pump may have lost prime. Turn power OFF; after 1 minute, turn
ON and depress Spray trigger.
The Pump Belt may be broken.
Turn power OFF and unplug
from the outlet. To check if a Pump
Belt has broken, you will need a flat
head screwdriver. Insert the blade
end into the lower slot of the Belt
Access door to release the lower
snap. If necessary, insert the blade
end into the upper slot to release the
upper snap. Examine the belt for
breakage. You should be able to see
the Pump Belt looped around the
motor shaft. If it is broken or missing,
please refer to the part numbers and
descriptions on page 15 before
calling Consumer Services. Complete
installation instructions will
accompany the replacement belt.
DirtLifter PowerBrush Does Not Turn.
Possible Causes Remedies
The Brush Belt or Pump Belt may be broken. Turn power OFF and unplug
from the outlet. To check if a Brush
Belt has broken, you will need a flat
head screwdriver. Insert the blade
end into the lower slot of the Belt
Access door to release the lower
snap. If necessary, insert the blade
end into the upper slot to release the
upper snap. Examine the belt for
breakage. If broken, refer to
pages 11-12.
13
1
1
2
2
4
4
WARNING:
To reduce the risk of fire,
electric shock or injury,
unplug appliance from outlet
before servicing.
Troubleshooting
5
5
1 1
Lift Here
Insert Screwdriver Blade Here
3