Form No F012507A 17 Part No 840186
MV650H PUSH Vacuum Owner’s Manual
Having one or more spare bags (840189) is a good way to reduce down time while dirty bags are being
cleaned.
Felt Bag (840194) accessory is great when used in dusty conditions.
HANDLING and TRANSPORTING
Using two people to lift unit is recommended. Lift holding the handle and front of nozzle. Make sure equipment
is properly secured before transporting. See MV650 series specifications on page 3 for unit weight.
NEVER lift the machine while the engine is running.
STORAGE
DO NOT store engine in an enclosed or poorly ventilated area where fuel fumes may
reach an open flame or spark from a furnace, water heater, clothes dryer or similar
devices.
DO NOT drain fuel in an enclosed or poorly ventilated area.
DO NOT smoke when draining fuel.
DO NOT remove gas cap while engine is running.
DO NOT park equipment on a steep grade or slope.
ALWAYS remove spark plug wire when servicing equipment to prevent accidental
starting.
ALWAYS keep hands and feet away from moving or rotating parts.
ALWAYS store fuel in approved safety containers.
If the equipment will not be used for 30 days or more, prepare as follows:
1. Make sure engine is cool.
2. Drain gasoline from carburetor and fuel tank to prevent formation of gum deposits.
3. Run engine until tank is empty and engine runs out of gas.
Fuel stabilizer (such as Sta-Bil
TM
) is an acceptable alternative for minimizing the formation of
gum deposits during storage. Add stabilizer to gasoline in storage container or fuel tank. Follow
stabilizer manufacturer’s instructions to determine proper mix ratio. Run engine at least 10
minutes after adding stabilizer to allow it to reach carburetor.
Hint!