Berkley B2ZRKL Water Pump User Manual


 
Page 8 F00633
Suction Connection
Installation
Suction Lift
Short length of straight pipe after reducer.
( 2 times pipe diameter minimum )
Suction
Gauge
Straight run, short as possible but
at least 6 times pipe diameter ("D")
after elbow to stabilize flow.
As close
as possible
Pipe diameter ("D")
4 x "D"
minimum
1 x "D" minimum
from bottom
Strainer / Foot Valve
To keep debris from entering
pump suction and to maintain
pump prime after shut-off.
Eccentric Reducer
flat side up.
See foundation
section.
Pump driven by remote
power source, direct coupling
or pulley/belt connection.
Support pipe
as required
NOTICE: All connections
must be air tight.
Standard or long
radius elbow.
Slope upward
to pump.
2114 1095
Recommended
Use pipe, tubing, or reinforced hose to make suction
connection. Hose must have sufficient strength to
resist collapse under the pressure differential that
occurs while pump is running.
Suction pipe size should be at least one commercial
pipe size larger than opening of pump inlet. Flow
velocity should not exceed 8 ft./sec.
Suction screen must screen out solids that could clog
pump impeller.
Suction screen area must be at least four times
suction pipe area.
Net Positive Suction Head Available (NPSHA) must
exceed Net Positive Suction Head Required
(NPSHR) by the pump or reduced performance and
severe pump damage may result.
All suction piping must have continuous rise to the
pump suction inlet. A 1/4 inch per foot minimum slope
is recommended.