24 Room Air Conditioner
AUTO CLEAN
ON/OFF
button
Operating Instructions
❏ During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy
Dehumidification Operation can be removed.
❏ During Auto Clean function, only Start/Stop button, Plasma button and AUTO CLEAN button are
available.
NOTICE
Auto clean (Optional)
1. Whenever you press the AUTO CLEAN button, Auto Clean Function will be
reserved and cancelled.
2. Auto Clean function works before and after cooling or dehumidification mode.
For details, refer to the below points.
3. When the unit is started after the reservation of Auto Clean ,the Cool Start
function operates and indoor Fan is started after 20 seconds.
4. When you press Start/Stop button to turn off the unit after the you have reserved
Auto Clean function, the air-conditioner circulates the indoor air in the Auto
Clean mode with no more Cooling or Dehumidification operation. It lasts for 30
minutes.
5. If you press the AUTO CLEAN button again during the product operation , Auto
Clean function will be cancelled.
Operation procedures when the remote control can't be used.
The operation will be started if the ON/OFF button is pressed.
If you want to stop operation, re-press the button.
Forced operation
Heat pump Model
Cooling Model
Room Temp. ≥ 24°C21°C ≤ Room Temp. < 24°C Room Temp. < 21°C
Operating mode Cooling Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High High
Setting Temperature
22°C22°C23°C24°C
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound
1 "beep".
If you want to stop the operation, re-press the button.