Beckett 240V Burner User Manual


 
Form No. 61283, Printed in the USA 02/11
www.beckettcorp.com
USA: R.W. Beckett Corporation • ph: (800)645-2876 • fax: (440)327-1064 | Canada: R.W. Beckett Canada Ltd. • ph: (800)665-6972 • fax: (519)763-5656
RESIDENTIAL BURNERS
AFG
Oil Burner 240V
240V
Chassis Plan
Reduces Investment Up To 65%
Reduces Storage Up To 85%
Speeds Service Calls
The Beckett Chassis Plan lets you stock a minimum number
of oil burners and still get maximum installation exibility. The
chassis represents 90% of the total burner cost, but one chassis
adapts to all ring rates commonly encountered in upgrading and
replacement jobs.
How to Order
Order Burner Chassis
1. Model AFG Burner Chassis
2. Type of Fuel Unit (single or two-stage)
3. Primary Control
Order Accessories
1. Specify type of supports required
2. Add any other items such as spare parts, related
controls, valves, etc.
Other AFG Components
Product Sheet
Features
Welded Relay Protection
Limited Recycle
Limited Reset
3 Status Lights
15 Second Lockout Time
Disable Function
Communication Ports (2)
Technician Pump Priming Mode
Interrupted or Intermittent Duty Ignition
Valve-On Delay / Motor-Off Delay
(Field programmable with Beckett add-on Display)
Thermostat / Operating (if applicable) and Limit Control
Compatible
CleanCut Pump
Integrated solenoid (50/60 Hz) valve.
Higher capacity design delivers up to 3
GPH at 100psi on the AFG burner.
The CleanCut has fewer moving parts
and reduces motor load.
240V PowerLight Beckett Igniter
Electrodes last approx. 50% longer.
Higher output voltage for reliable ignition.
Approximately 75% lower input amps.
PSC Motor - 50/60 Hz
Lower amp draw & cooler operation.
Delivers more power with the PSC
design (permanent split capacitor).
Proven durability after 10 years of high
reliability in the eld.
Ball bearings for longer life.
Beckett Sound Cover (optional)
Reduces near-burner air and
component noise.
Enhances burner appearance.
Easy to use knockout and adapter kit
when ducted air is required.
The Beckett GeniSys
TM
Advanced Burner Control is a 208/240
Vac, 50/60 Hz primary safety control for residential and light
commercial oil burners used in boiler, furnace, and water
heater applications having ring rates less than 20 GPH.
The GeniSys is used with a suitable cad cell ame sensor
to control the oil burner motor, igniter, and optional solenoid
valve. It has 24 Vac thermostat terminals (if applicable)
compatible with both mechanical and many power stealing
thermostats. It can also provide interrupted or intermittent
duty ignition.
Description / Applications
Beckett GeniSys Control 240V
de