RESIDENTIAL BURNERS
AFG
Oil Burner 240V
240V
Advanced Components
• 240V GeniSys Burner Control
• CleanCut Pump
• 240V PowerLight Beckett Igniter
• PSC Motor
• Beckett Sound Cover (optional)
Description
The 240 volt AFG burner has technically advanced components to meet increased demand for improved burner
performance for residential, pressure washers and light commercial applications. These advanced components are
available on our B2000 series chassis. The 240 volt AFG’s performance-enhancing features will help you meet
today’s toughest heating system and pressure washer challenges.
Product Sheet
Outputs:
◦ Motor:
208/240 Vac, 5 full load amps (FLA), 30 locked rotor amps (LRA)
◦ Igniter: 208-240 Vac, 3 A @ 0.7 PF min
◦ Solenoid Valve: 208-240 Vac, 1 A @ 0.7 PF min
◦ Thermostat Anticipator Current: 0.1 A (if applicable)
◦ Thermostat Voltage: 24 Vac (if applicable)
Electrical Ratings
Inputs:
◦ Voltage: 220-240 Vac (177 to 264 Vac)
◦ Current: 100 mA nominal (150 mA max at 264 Vac)
◦ Frequency: 50/60 Hz
Beckett GeniSys
Control Part No.
Lockout
Time
Valve-on
delay time
1
Motor-off
delay time
1
Replaces Honeywell:
7560A 0000 15 sec - - R8184G
7560B 1500 15 sec 15 sec - -
7560P 1515 15 sec 15 sec 15 sec -
7560P 1530 15 sec 15 sec 30 sec -
7560P 152M 15 sec 15 sec 2 min -
1 - Valve-on delay and motor-off delay timings on all models are programmable with Beckett snap-on
programming display. Other factory set timings are available. Contact Beckett for alternate timings.
GeniSys Controls:
Models and Settings
Flame Retention Heads
The maximum fi ring rates shown
are for 60HZ operation. For 50HZ
operation the maximum fi ring rate for
each head is reduced by about 20%.