Instruction Manual – Model AFII Oil Burner
Beckett
Figure 3 - HLX Arrangement
6
AIR
DIAL
SETTING
Stop Screw AFII 85 AFII 100 AFII 150
0 0.40-0.65 0.50-0.65 0.75-1.00
1 - 0.60-0.75 0.85-1.10
2 - 0.65-0.80 0.95-1.15
3 0.60-0.75 0.65-0.90 0.95-1.20
4 - 0.75-0.95 1.10-1.25
5 0.70-0.85 0.85-1.00 1.15-1.35
6 - 0.95-1.10 1.15-1.40
7 - - 1.25-1.50
8 - - 1.30-1.50
Firing Rate at
140 psig
AFII 85 AFII 100 AFII 150
0.40 to 0.65 3 - -
0.60 to 0.75 4 3 -
0.70 to 0.85 5 4 -
0.75 to 1.00 - 5 2
0.95 to 1.20 - - 3
1.15 to 1.35 - - 4
1.25 to 1.50 - - 5
FIRING
RATE
Prepare burner & site
SK9644A
SK9639