BEA GT 400 Door User Manual


 
BUTTON PARAMETER VALUE BUTTON PARAMETER VALUE
SENSITIVITY
Door Closed = 6
Door Open = 7
0 (min)
9 (max)
INTERFACE
New Style
Old Style (LO21, B, K,
P, S, U, LO-LINX, MC15)
1
2
AUTO LEARN
0 = 30 sec
9 = Innite
0 (min)
9 (max)
SETUP / WAND
Door Closed = 1
Door Open = 2
Restore to Default
1
2
9
OUTPUT CONFIG.
NO
NC
1
2
HOLD TIME
0 = 0.5 sec
9 = 9 sec
0 (min)
9 (max)
IMMUNITY
Low (Normal)
Medium (Rain)
High (Snow) *
* - BGIII-C
1
2
3 *
FREQUENCY
Normal Mode; Low
Normal Mode; High
Quiet Mode; Low
Quiet Mode; High
1
2
3
4
SWING ACT COM SAF STALL STALL COM SWING ACT COM SAF STILL STALL COM
Besam 300 13 12 11 15, 17 16, 18 HUNTER ACT RTN SAF 1 SAF 2 RTN
Besam M/P 3 4 9 5 13 KM K Green White Red Yellow White
DOM Yellow Grey Blue Purple Grey STANLEY L Orange Yellow Red Blue Yellow
GT 300/400 Black Red White White Red STANLEY M/P 2 1, 8 7 7 1, 8
GT MAG 6 Black 5 Red 4 White 3 Violet 5 Red STANLEY 521 TB4-5 TB4-4 TB4-8 TB4-10 TB4-9
HORTON 4190 2 3, 6, 8 4 10 3, 6, 8 TORMAX TDA 2 1, 3, 6, 8 8 & 9 7 1, 3, 6, 8
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the
following workday to call BEA., leave the door inoperable until satisfactory repairs can be made. Never sacrice the safe operation of the automatic door or
gate for an incomplete solution. The following numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com.
US and Canada:
Canada:
Northeast:
1-866-249-7937
1-866-836-1863
1-866-836-1863
Southeast:
Midwest:
West:
1-800-407-4545
1-888-308-8843
1-888-419-2564
Page 2 of 2 75.5362.01 20090210
8 Door Control Connections
9 Company Contact
6 Sensing Zone Adjustment
7 Congurations
1
4
3
5
6
2
1ST ROW OF IR
THRESHOLD
2ND ROW OF IR
3RD ROW OF IR
4TH ROW OF IR
Pattern Depth
1: Deep (Threshold ON)
2: Medium (Threshold ON - OPEN)
3: Limited (Threshold ON)
4: Deep (Threshold OFF)
5: Medium (Threshold OFF - CLOSED)
6: Limited (Threshold OFF)
1
4
3
5 6
2
1ST ROW OF IR
THRESHOLD
2ND ROW OF IR
3RD ROW OF IR
4TH ROW OF IR
7 8 9
Pattern Width (Open / Closed)
1: Wide (CLOSED DOOR) 4: Asymmetric Right Narrow 7: Asymmetric Left Wide
2: Middle (OPEN DOOR) 5: Narrow Left 8: Asymmetric Right Wide
3: Asymmetric Left Narrow 6: Narrow Right 9: Center Narrow
NOTE: When pattern width or depth is changed, a setup of the new pattern size will automatically be triggered
once a value key has been pressed.
Pattern Width, Depth & Sensitivity all
have independent door closed and
door open values.
ENSURE COMPLIANCE WITH ALL APPLICABLE CURRENT SAFETY STANDARDS (I.E. ANSI A156.10).