BEA Eagle HM Home Security System User Manual


 
75.1038 V3 Jun 2005 [Rev. June 10, 2005] Page 2 of 8
SAFETY
PRECAUTIONS
Shut off all power going to the header before attempting any wiring procedures.
Maintain a clean & safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected
reactions by the door.
Always check placement of all wiring and components before powering up to insure that moving door
parts will not catch any wires and cause damage to equipment.
Ensure compliance with all applicable safety standards upon completion of installation
From behind, before installation From the front, after installation
Paste the template at
desired location.
Drill as instructed.
Insert screws but do not screw
them fully in.
If possible, pass the cable
where it is supposed to go
through.
If you don't want to drill your profile for
the cable, you can cut the wire opening
footprint as shown in the picture.
Run the cable through the wire
passage hole just below PCB.
Position the sensor and tighten
the two screws. Make sure you
leave enough cable to reach the
terminal block.
MECHANICAL
INSTALLATION -
OPENING THE
SENSOR
MECHANICAL
INSTALLATION -
PREPARATION
FOR MOUNTING
THE SENSOR
ELECTRICAL
INSTALLATION -
CABLING &
CONNECTION
12-24 V AC/DC COM NO NC