BEA 80.0068.03 Door User Manual


 
SIZE:
DRAWN BY:
B
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY:
KJG KJG
SCALE: DATE:
NONE 09 AUG 05
PART NO:
SHEET
1 OF 1
NOTES: 1 ) THE MAGNETIC REED SWITCH SHALL OPEN AT APPROX. 65-70 DEGREES TO INHIBIT THE SWING SIDE SUPERSCANS AND SHALL STAY OPEN UNTIL CLOSING CYCLE OCCURS AND THE
SWITCH MAKES AT 65-70 DEGREES.
2 ) LO21 DIP SWITCHES: 1-5 LOCKOUT TIME WILL VARY, #6-8, (NOT USED).
3 ) IF USING A MAGNETIC REED SWITCH TO INHIBIT SWING SIDE SUPERSCANS, SET CONTROL FUNCTION DIAL TO 6. IF NOT USING INHIBIT SWITCH, SET CONTROL FUNCTION DIAL TO 5.
4 ) IF BODYGUARD HAS DOM INTERFACE CIRCUIT BOARD, IT MUST BE REMOVED.
TITLE: DOROMATIC ASTRO-SWING WITH
PARALLAX 2 SYSTEM (LO21)
Q-DISCONNECT ON APPROACH SIDE
80.0078.02
MASTER MOTOR (VOLTAGE)
RED +
BLACK -
MAGNETIC REED
SWITCH
COM.
N/C
OPTION
(SEE NOTE #1)
AUTO
OFF
HOLD OPEN
(SEE NOTE #3)
FUNCTION
LATCH
(BLUE) SAFETY
(YELLOW) ACTIVATE
(GRAY) COMMON
(PURPLE) STALL
SUPERSCAN QUICK-
DISCONNECT CABLE
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC. FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT
1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS, CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT LEAVE ANY
PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE
THE SAFE OPERATION OF THE AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM