Bard WG5S1 Air Conditioner User Manual


 
Form No. S3396-1112
Supersedes S3396-212
Page 12 of 12
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
www.bardhvac.com
Due to our continuous product improvement policy,
all specifications subject to change without notice.
Before purchasing this appliance, read important energy cost
and efficiency information available from your retailer.
Form No.
S3396
November, 2012
Supersedes S3396-212
dellatsnIdleiF-stiKnoisrevnoCteltuOylppuSpoT
SLEDOMHTIWDESU EGIEB-XROLOCTINU YARGEYEKCUB-4ROLOCTINU EZNORBKRAD-8ROLOCTINU
S5GW,S4GW,S3GWX-5GW-OST4-5GW-OST8-5GW-OST
seludoMlortnoCgninoitidnoCri
A
)detoNsatpecxEsledoMllA(
CPH 1 CPL 2 MCC 3 CAL 4 KS 5 edoCdellatsnIyrotcaF traPdellatsnIdleiF
DTSDTSDTSXA/N
DTSDTSDTS
H82-AMC
DTSDTSDTS
ylnOdellatsnIdleiF A-1S3GWrof411KS
DTSDTSDTS
ylnOdellatsnIdleiF A-1S4GWrof111KS
DTSDTSDTS
ylnOdellatsnIdleiF A-1S5GWrof511KS
seirosseccAdellatsnIdleiFlanoitpO
NOITPIRCSED REBMUNTRAP
)teeF000,01-0006(tiKhctiwSerusserPedutitlAhgiHsaGlarutaN 981-0268
.selbaTedutitlAdnaecifirOeeS.tnetnocUTBsaGdnaedutitlAnopUgnidnepeDderiuqeReByaMegnahCecifirOsaGlarutaN:etoN
)edutitlAteeF0006-0(tiKnoisrevnoCsaGenaporP 1-KCGW
)edutitlAteeF000,01-0006(tiKnoisrevnoCsaGenaporP 2-KCGW
)tnevlacitrevtoof5rofstrapllasedulcnI(tiKtneVlacitreV A5-KVV
A5-KVVrofnoitcesepiptnevlacitrevtoof1lanoitiddA 102-0268
A5-KVVrofnoitcesepiptnevlacitrevtoof2lanoitiddA 071-0268
A5-KVVrofnoitcesepiptnevlacitrevtoof3lanoitiddA 002-0268
A5-KVVrofnoitcesepiptnevlacitrevtoof5lanoitiddA 171-0268
*125,000 BTU input model is not NOx certified.
snoitpOnoitalitneV
sledoM S5GW,S4GW,S3GW
noitpircseD
dellatsnIyrotcaF
.oNedoC
dellatsnIdleiF
.oNtraP
)dradnatS(etalPffO-knalB B5-POBSGW
tsuahxE/wnruteRgnirpSgnitaludoM-rotalitneVlaicremmoC V5-PMVRCSGW
tsuahxE/wgnitaludoMylluF)lanretnI(rezimonocE 1 E5-MFIESGW
tsuahxE/wtloV032-rotalitneVyrevoceRygrenE 2 R-A5A-VRESGW
tsuahxE/wtloV064-rotalitneVyrevoceRygrenE 2 R-A5C-VRESGW
1 .noitareporosserpmocerutarepmetwolrofrezimonocehtiwderiuqersilortnoctneibmawoL
2 .noitceleskcolblanimrethtiw)etar(sdeepstsuahxednaekatnifonoitcelestnednepednI
)eznorBkraD="8";yarGeyekcuB="4";egieB="X"(tinuhctamotdeificepsebtsumnoitporoloC
MODEL
NUMBER
CONTROL
MODULES
(See Table)
REVISION
CODE
COIL OPTIONS
X - Standard
1 - Phenolic Coated Evap.
2 - Phenolic Coated Cond.
3 - Phenolic Coating on
both coils
COOLING
CAPACITY
3 - 3 Ton
4 - 4 Ton
5 - 5 Ton
WG 3 S 1 A X B B X X X X X
SPECIALTY
PRODUCTS
(Non-Standard)
C= Canadian Approval
OUTLET OPTIONS
X - Front (Standard)
T - Top
COLOR OPTIONS
X - Beige (Standard)
4 - Buckeye Gray
8 - Dark Bronze
FILTER OPTIONS
X - 2-inch Pleated
W - 1-inch Washable
EMISSIONS
X - Standard
N - NOx Certified*
VENT OPTIONS
(See Table)
VOLTS & PHASE
A - 230/208-60-1
B - 230/208-60-3
C - 460-60-3
STEP CAPACITY
HEATING INPUT
A = 50,000
B = 75,000
C = 100,000
D = 125,000*
Air Conditioning Wall-Mount Model Nomenclature
STD = Standard equipment for these specified models.
1 HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
2 LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
3 CCM. Compressor control module has adjustable 30-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be
2-minutes plus 10% of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with 1
retry) for high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control.
4 LAC. Low ambient control permits cooling operation down to 0°F.
5 SK. Start capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque 9x. Not used for -B or -C three phase models.