Bard WA5S Air Conditioner User Manual


 
Form No. S3378-1112
Supersedes S3378-712
Page 12 of 12
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
www.bardhvac.com
Due to our continuous product improvement
policy, all specifications subject to change
without notice.
Before purchasing this appliance, read important energy
cost and efficiency information available from your retailer.
sledoM sledoMllA
noitpircseD
dellatsnIyrotcaF
.oNedoC
dellatsnIdleiF
.oNtraP
etalPffO-knalB B5-POB
repmaDriAhserFdezirotoM M5-DAFM
tsuahxEhtiwdezirotoM-rotalitneVlaicremmoC V5-PMVRC
yplahtnE,snoisreVloohcS-rezimonocE 4 S5E-SMWNOCE 32
yplahtnE,.gdlBtnempiuqE-rezimonocE 5 W5E-TMWNOCE 2
pmeTBD,.gdlBtnempiuqE-rezimonocE 5 T5T-TMWNOCE 2
tloV032-rotalitneVyrevoceRygrenE 3 R5A-FVRE 1
tloV064-rotalitneVyrevoceRygrenE 3 R5C-FVRE 1
)deriuqeR(FVREroftiKrooD A/N-5KDMW 3
Ventilation Options
1 Intake and exhaust can be independently adjusted.
2 Insert color to match unit ("X" = Beige; "4" = Buckeye Gray; etc.)
3 WMDK Door Kit must be ordered in addition to ERVF Assembly and ECONWMS & color matched to unit ("X" = Beige; "4" = Buckeye Gray; etc.)
4 Partial Full Flow (75% of Rated Cooling CFM). All ECONWMS versions have 3" deep intake hood.
5 Full Flow (100% of Rated Cooling CFM). ECONWMT2 and 3 have 16" deep intake hood; ECONWMT-5 has 18" deep intake hood.
WA 3S 3 A 10 B P X X X X
Note: For 0KW and circuit breakers (230/208 Volt) or rotary disconnect (460 Volt) applications, insert 0Z in the KW field of the model number.
CONTROL MODULES
(See Chart Below)
COLOR OPTIONS
X - Beige (Standard)
1 - White
4 - Buckeye Gray
5 - Desert Brown
8 - Dark Bronze
A - Aluminum
S - Stainless Steel
COIL OPTIONS
X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator
& Condenser
OUTLET OPTIONS
X - Front (Standard)
CAPACITY
3S - 3 Ton
4S - 4 Ton
5S - 5 Ton
KW
VOLTS & PHASE
A - 230/208/60/1
B - 230/208/60/3
C - 460/60/3
REVISION
WA - 3
WL - 2
FILTER OPTIONS
P - 2 inch Pleated
MERV 8
VENTILATION OPTIONS
(See Chart Below)
STD = Standard equipment for these specified models.
1 HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
2 LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
3 CCM. Compressor control module has adjustable 30-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the
delay-on-make will be 2-minutes plus 10% of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also
provides the lockout feature (with 1 retry) for high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control.
4 LAC. Low ambient control permits cooling operation down to 0°F.
5 ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low
pressure controls.
6 SK. Start kit standard on all -A single phase models only. Is not used or available for -B or -C three phase models.
7 DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function
to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status.
seludoMlortnoCgninoitidnoCriA
sledoMllA
SNOITPOLORTNOCELBALIAVA
CPH 1 CPL 2 MCC 3 CAL 4 RLA 5 KS 6 CDD 7
edoCdellatsnIyrotcaF traPdellatsnIdleiF
DTSDTSDTSDTSX
A/N
DTSDTSDTS
z
DTSH82-AMC
DTSDTSDTS
zz
DTSJylnOyrotcaF
DTSDTSDTS
zz
DTS
z
V 7 ylnOyrotcaF
Air Conditioning Wall-Mount Model Nomenclature
Form No.
S3378
November, 2012
Supersedes: S3378-712
MODEL
NUMBER
WA – Right Hand
WL – Left Hand