Bard W17A Air Conditioner User Manual


 
Form No. S3397-1112
Supersedes S3397-712
Page 11 of 12
1 Intake and exhaust can be independently adjusted.
2 Insert color to match unit ("X" = Beige; "4" = Buckeye Gray; etc.)
3 WMDK Door Kit must be ordered in addition to ERVF Assembly and ECONWMS & color matched to unit ("X" = Beige; "4" = Buckeye Gray; etc.)
4 Partial Full Flow (75% of Rated Cooling CFM). All ECONWMS versions have 3" deep intake hood.
5 Full Flow (100% of Rated Cooling CFM). ECONWMT2 and 3 have 16" deep intake hood; ECONWMT-5 has 18" deep intake hood.
6 Model W24A1-C only.
sledoM 1A42W,1A81W,1A71W 1A63W,1A03W 1A06W,1A84W,1A24W
noitpircseD
dellatsnIyrotcaF
.oNedoC
dellatsnIdleiF
.oNtraP
dellatsnIyrotcaF
.oNedoC
dellatsnIdleiF
.oNtraP
dellatsnIyrotcaF
.oNedoC
dellatsnIdleiF
.oNtraP
dradnatS-repmaDriAhserFcirtemoraBX2-DAFBX3-DAFBX5-DAFB
etalPffO-knalBB2-POBB3-POBB5-POB
repmaDriAhserFdezirotoMM
2-DAFMM3-DAFMM5-DAFM
tsuahxE/wnruteRgnirpS-rotalitneVlaicremmoCV2-VRCV 3-SVRCV5-SVRC
tsuahxE/wnruteRrewoP-rotalitneVlaicremmoC------P
3-PVRCP5-PVRC
yplahtnE,snoisreVloohcS-rezimonocE 4 S2E-SMWNOCE 32 S3E-SMWNOCE 32 S5E-SMWNOCE 32
yplahtnE,.gdlBtnempiuqE-rezimonocE 5 W2E-TMWNOCE 2 W3E-TMWNOCE 2 W5E-TMWNOCE 2
pmeTBD,.gdlBtnempiuqE-rezimonocE 5 T2T-TMWNOCE 2 T3T-TMWNOCE 2 T5T-TMWNOCE 2
tloV032-rotalitneVyrevoceRygrenE 3 R2A-FVRER
3A-FVRE 1 R5A-FVRE 1
tloV064-rotalitneVyrevoceRygrenE 3 A/N2C-FVRE 6 R3C-FVRE 1 R5C-FVRE 1
)deriuqeR(FVREroftiKrooDA/N-2KDMW 3 A/N-3KDMW 3 A/N-5KDMW 3
Ventilation Options
Specialty Products 2
(Non-Standard)
SERIES |
| CONTROL MODULES
(See Chart Below)
REVISION
VOLTS & PHASE |
A - 230/208/60/1
B - 230/208/60/3
C - 460/60/3
KW
1
COLOR OPTIONS
X - Beige (Standard)
1 - White
4
- Buckeye Gray
5 - Desert Brown
8 - Dark Bronze
A - Aluminum
S - Stainless Steel
FILTER OPTIONS
X - 1-inch Throwaway (Standard)
W - 1-inch Washable
P - 2-inch Pleated (MERV 8)
| COIL OPTIONS
X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator
and Condenser
| OUTLET OPTIONS
X - Front (Standard)
T - Top (on W30A and
W36A Models)
NOMINAL
CAPACITY |
17 - 1½ Ton
18 - 1½ Ton
24 - 2 Ton
30 - 2½ Ton
36 - 3 Ton
42 - 3½ Ton
48 - 4 Ton
60 - 5 Ton
W 36 A 1 A 10 X X X X X X
VENTILATION OPTIONS
(See Table Below)
Air Conditioning Wall-Mount Model Nomenclature
1 For 0KW and circuit breakers (230/208 Volt) or toggle disconnects (460 Volt) applications, insert 0Z in the KW field of the model number.
See Page 8 for available Factory Installed KW options and Page 9 for Field Installed Heater Packages.
2 Insert “D” for dehumidification with hot gas reheat — Models W42 - 60 only. See Form 7960-572 for complete details.
TYPE
Air Conditioner
STD = Standard equipment for these specified models.
1 HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
2 LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
3 CCM. Compressor control module has adjustable 30-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2-
minutes plus 10% of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with 1 retry) for
high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control.
4 LAC. Low ambient control permits cooling operation down to 0°F. LAC is fan-cycling control for outdoor fan motor on all models except W17A1, which is modulating control.
5 ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.
6 SK. PTCR start kit can be used with all -A single phase models. Increases starting torque 2-3x. Not used for -B or -C three phase models. Do not use if SK111 is used.
7 SK. Start capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque 9x. Not used for -B or -C three phase models. Do not use if
CMC-15 is used.
8 ODT. Outdoor thermostat is adjustable from 0 to 50°F. It is suitable for use as a compressor cut-off thermostat.
9 DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data
such as temperature, as well as digital data such as airflow, compressor status or filter status. Special economizer required; consult factory.
“V” control module should be ordered in conjunction with direct digital controller (DDC) model TCS24. Refer to DDC specification sheet S3280 for more information.
Option not available for Model W18A.
Use option N for Alarm Relay on Model W18A only.
seludoMlortnoCgninoitidnoCriA
detoNsAtpecxEsledoMllA
1A71W
yrotcaF
ylnO
CPH
1
CPL
2
MCC
3
CAL
4
RLA
5
KS
6
KS
7
TDO
8
CDD
9
edoCdellatsnIyrotcaF traPdellatsnIdleiF
DTSDTSDTS XA/NA/N
DTSDTSDTS
z
E82-AMCA/N
DTSDTSDTS
zz
JylnOyrotcaFJ
DTSDTSDTS
zz
K82-AMCdna51-CMCA/N
DTSDTSDTS
zzz
MylnOyrotcaFM
DTSDTSDTS
z
ylnOA81W,NA/NA/N
DTSDTSDTS
z
ylnOdellatsnIdleiF51-CMC51-CMC
DTSDTSDTS
z
ylnOdellatsnIdleiF41-AMCA/N
DTSDTSDTS
zz z
V
ylnOyrotcaFA/N
DTSDTSDTS
z
ylnOdellatsnIdleiF
A63-81Wrof32-AMC
A06-24Wrof42-AMC
A/N
DTSDTSDTS
z
ylnOdellatsnIdleiF111KS111KS
11
12
11
11
11
11
11
12
11