3. Lamp replacement procedure
3. LAMP REPLACEMENT PROCEDURE
Overview
• Reset lamp runtim e
• Removing the rear cover
• Removing the lamp
• Installing the lamp
• Installing the rear cover
Resetting the lamp runtime requires access to the hidden m enu of the projector. Select More... in the Lamps
menu, and enter the password (by d efault 0000) followed by Enter to get access.
3.1 Reset lamp runtime
When to reset the lamp runtime?
The lamp runtime should only be reset when placing a new lamp.
WARNING: Lamp runtime reset as well as the lamp replacement can only be done by a Barco authorized
technician.
Necessary tools
No tools.
How to reset the lamp runtime?
1. Press MENU to activate the Tool bar
2. Press → to select the Lamp item
3. Press ↓ to Pull down the L amps m enu
4. U se ↑ or ↓ to select Res et runtime
5. Press → to pull down t he menu
6. U se ↑ or ↓ to select the lamp to be r eset
Image 3-1
7. Press ENTER
R59770361 SIM 5W LAMP KIT 28/11/2008