Axor 32073XX1 Plumbing Product User Manual


 
6
Set the High Temperature Limit Stop (optional)
Use a 4 mm Allen wrench to push the screw cover into
the handle. Retrieve the screw cover when the handle
is removed.
Use the 4mm Allen wrench to loosen the handle screw
4 complete revolutions.
Remove the handle.
Replace the high temperature limit stop so that the pin
on the cartridge is in the desired slot on the limit stop.
Note: the temperatures given in the diagram assume
a water heater temperature of 140° F, a cold water
temperature of 50° F and a water pressure of 45 PSI.
Replace the ange. Replace the handle screw. Use
Remove the ange.
Remove the handle screw from the stem of the car-
tridge.
Remove the high temperature limit stop.
the Allen wrench to turn the screw 4 revolutions.
Replace the handle. Finish tightening the handle screw. Turn on the water and test the faucet.
English