Axor 18115001 Indoor Furnishings User Manual


 
4
Insert a measuring device in the spout outlet. Measure
from the port on the rough to the end of the plaster shield.
Record this measurement (X). Add 2” to X. Cut the spout
connector so that it is X + 2” long.
Wrap the threads on the spout connector with Teflon
thread tape (1).
Screw the spout connector into the spout port with a 12
mm Allen wrench (not included) (2). The spout connector
should extend 1 3/16” outside the surface of the finished
wall.
Install the handle sealing rings, escutcheons, nuts, snap
connectors and screws, and color rings (3). The blue
color ring should be on the right, the red color ring on the
left.
1
2
3