Axor 04128XX0 Plumbing Product User Manual


 
12
Install the escutcheon.
Justify the handle.
Rinse the debris from the filters, using a
soft toothbrush if necessary. Do not at-
tempt to remove the screens.
Lubricate the o-rings with white plumbers
grease.
Hold the stop unit steady. Install the ther-
mostatic cartridge.
Failure to hold the stop unit
steady may result in damage
to the ceramic plates.
Grasp the wrench flats on the cartridge stop unit
with a wrench.
Hold the stop unit still with one wrench.
Use a second wrench or a 17mm deep
socket wrench to unscrew and remove the
thermostatic cartridge.
Failure to hold the stop unit steady
may result in damage to the ceramic
plates.