Aube Technologies TH113 AF Thermostat User Manual


 
400-230-000-C 5/12/05 2/2
3.3 Master Thermostat - Installation and Wiring
WARNING: Make sure all slave units are in STANDBY mode.
Required parts: TH113-A/F/AF (12VDC),
TH114-A/F/AF (12VDC),
TH115-A/F/AF (12VDC) or
TH116-A/F/AF (12VDC)
Location: anywhere easily accessible to users.
Temperature control: AF (ambient with floor limit) / A (ambient)
Install the master thermostat in the controlled area.
Choose a location about 5 ft. above the floor in an area where the tempera-
ture is stable.
Avoid locations where there are air drafts (top of staircase, air outlet), dead air
spots (behind a door), direct sunlight or concealed chimneys or stove pipes.
Temperature control: F (floor)
Can be installed anywhere.
s Wire the 12 VDC base to the nearest slave unit.
The floor sensor must be installed in an area where average temperature can be
read. The cable must follow the wall down to the floor and must not cross any
heater wires or be directly on or adjacent to a heating wire.
For maximum performance, the sensor probe should be centered between the
wires in the mat (max. 80°C).
t Push the excess wire into the wall, secure the base using the provided screws
and wall anchors, and install the TH11x thermostat onto the base.
u Once the thermostat is installed, return power to heating system and switch all
slave units and the master thermostat to ON.
3.4 Slave Units - GFCI Test
We recommend you test the GFCI immediately after installing the thermostat, and
once a month thereafter to ensure it is operating properly.
If the test warning light comes ON during normal operation, cut power to heating
system from the main power panel and verify the installation.
n Slide the protective door upwards and make sure the switch is ON.
o Press TEST.
The test is successful if the TEST warning light is ON and power is cut off.
If the test fails (first installation test):
a. Verify installation
b. Check the load wires
c. Once you've identified the problem, run the GFCI test again
If the test fails (monthly maintenance):
a. Cut power to heating system from the main power panel and call customer
service
p When the test is successful, reset the slave unit by switching from ON to
STANDBY then back to ON.
q Repeat steps 1 to 3 for all slave units.
Technical Specifications
Temperature:
- Operation: 32°F to 122°F (0°C to 50°C)
- Storage: -4°F to 122°F (-20°C to 50°C)
TH113/TH114/TH115/TH116 (A/F/AF-12VDC)
NOTE: Refer to the TH11x user guide for techni-
cal specifications.
CT230-120GA/120GB/240GA/240GB
Service
If you have any questions concerning the
installation of the master thermostat or slave
units, contact our technical support team at:
Montreal area: (450) 358-4600
Canada / U.S.: 1-800-831-AUBE (2823)
Fax: (450) 358-4650
Email: service@aubetech.com
Monday to Friday from 8:30 AM to 5:00 PM EST.
For more information on our products, visit us at
www.aubetech.com
Warranty
AUBE TECHNOLOGIES INC.
ONE (1) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship
defects for a one year period following the initial
date of purchase. During this period, AUBE
Technologies Inc. will repair or replace, at our
option and without charge, any defective product
which has been used under normal conditions.
The warranty does not cover delivery costs and
does not apply to products poorly installed or
randomly damaged following installation. This
warranty cancels and replaces any other
manufacturer's express or implied warranty as
well as any other company commitment.
AUBE Technologies Inc. cannot be held liable for
related or random damages following the
installation of this product. The defective product
as well as the purchase invoice must be returned
to the place of purchase or mailed, prepaid and
insured, to the following address:
Aube Technologies Inc.
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec,
Canada J2X 5K8
Power supply 12 V from remote unit
Maximum
slave units
up to 10 slave units per
master thermostat
Wire gauge 20 AWG
Size (H • W • D)
BASE
4.63 x 2.7 x 0.61 in.
(117.5 x 68.3 x 15 mm)
Supply
- PB112-120
- PB112-240
1800 W @ 120 VAC
60 Hz, 15 A resistive
3600 W @ 240 VAC
60 Hz, 15 A resistive
GFCI GA=5 mA / GB=30 mA
Certification c CSA us
Size (H • W • D)
BASE
4.63 x 2.7 x 1.45 in.
(117.5 x 68.3 x 37 mm)
Size (H • W • D)
INTERFACE
4.67 x 2.74 x 0.67 in.
(118.6 x 69.6 x 17 mm)