Aube Technologies TH106 Thermostat User Manual


 
TH106 400-106-001-D 12/8/05 3/3
r Press Mode to exit the programming mode.
NOTE: If no button is pressed for 60 seconds, the thermostat will
automatically exit the programming mode.
During a power outage, the settings are stored in memory. However,
only the thermostat’s clock must be re-adjusted if the power failure
lasts more than 2 hours. When power comes back, the thermostat
will return to the operating mode that was active prior to the power
failure.
Power: 120/240 VAC, 50/60 Hz
Minimum load: 2 A (resistive only)
500 W @ 240 VAC
250 W @ 120 VAC
Maximum load: 16.7 A (resistive only)
2000 W @ 120 VAC
4000 W @ 240 VAC
Display range: 0°C to 60°C (32°F to 140°F)
Display resolution: 0.5°C (1°F)
Setpoint range: 5°C to 30°C (40°F to 86°F)
Setpoint interval: 0.5°C (1°F)
Storage: -20°C to 50°C (-4°F to 120°F)
Approval: c UL us
Aube warrants this product, excluding battery, to be free from defects
in the workmanship or materials, under normal use and service, for a
period of three (3) years from the date of purchase by the consumer.
If at any time during the warranty period the product is determined to
be defective or malfunctions, Aube shall repair or replace it (at Aube's
option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to
the place from which you purchased it, or
(ii) contact Aube. Aube will make the determination whether the
product should be returned, or whether a replacement product can
be sent to you.
This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by Aube that the defect or mal-
function was caused by damage which occurred while the product
was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product
within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCI-
DENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-
RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF
THIS PRODUCT. Some provinces and states do not allow the exclu-
sion or limitation of incidental or consequential damages, so this limi-
tation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces and states do not allow limitations on
how long an implied warranty lasts, so the above limitation may not
apply to you.
This warranty gives you specific legal rights, and you may have other
rights which vary from province or state to another.
If you have any questions about the product installation or operation,
or concerning the warranty, contact us at:
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: aube.service@honeywell.com
For more information on our products, go to
www.aubetech.com
u
Power Outage
8.
v
Troubleshooting
9.
PROBLEM SOLUTIONS
Thermostat is hot.
This condition is normal. Under normal
operation, the thermostat housing can
reach a temperature between 35°C (95°F)
and 40°C (104°F).
Heater is always On.
The thermostat has not been correctly
wired.
Thermostat indicates
that heating is On, but
the heater is not On.
The thermostat has not been correctly
wired.
Wrong temperature is
displayed.
The thermostat is exposed to air draft.
Eliminate the draft.
The sticker on the thermostat’s screen has
not been removed.
Wrong time is displayed.
The thermostat was without power for
more than 2 hours.
Temperature does not
change according to the
programmed schedule.
Check that the thermostat is in Automatic
mode. Check the schedule and clock set-
tings.
Display disappears and
reappears after a few
minutes.
The thermal protection device on the
heater is open. This can happen after a
power failure or if the heater is obstructed
by furniture or curtains.
Display looks faded
when heating is acti-
vated
The heating system is less than the
required minimum load. This thermostat
cannot be used below that rating.
w
Technical Specifications
10.
;
Warranty
11.
Customer Assistance
12.
As an ENERGY STAR
®
partner, Aube Technologies has
determined that this product meets the E
NERGY STAR
guidelines for energy efficiency.