Atlas 240 Series Indoor Furnishings User Manual


 
3
598-1094-04
❒ Remove the existing light fixture.
Install the mounting strap as shown using two screws
that fit your junction box.
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒ Route the light control’s wires through the large
gasket holes.
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
White to
White
Black to
Black
Junction box ground wire to
green ground screw on fixture.
Gasket
Mounting
Strap
Mounting
Bolt
Rubber
Plug
Mount the Light Control
Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
Align the three slots in the decorative shell with the
bulb holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
Lock Nut
To avoid water damage and electrical shock,
keep bulb holders 30° below horizontal.
❒ Adjust the bulb holders by loosening the lock nuts but
do not rotate the bulb holders more than 180° from
the factory setting. When screwing in the floodlamps,
do not overtighten.
Keep bulbs at least
1" (25 mm) from the
sensor. Do not allow
the bulbs to block
the lens.Lens
Push the rubber plug firmly into place.
If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.
Shell Slot
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.