Atlas 240 Series Indoor Furnishings User Manual


 
© 2008 Atlas Lighting Products, Inc. 598-1094-04
Models MLGC240B
MLGC240W
TEST
2 Shells
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Dual Light Level.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
TEST 1 5 20
ON-TIME
Off 3 6 Dusk to
Dawn
DUAL LIGHT LEVEL
Put ON-TIME switch on the sensor bottom to TEST
and the Dual Light Level switch OFF.
OPERATION
* resets to Auto Mode at dawn.
ON-TIME
TEST 1 5 20
... back on.
1 Second OFF
then...
Put the ON-TIME switch in the
1, 5, or 20 minute position.
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
This package includes:
Light Control
Sensor
Cover
Plate
Bulb
Holders
Plastic Hanger
Rubber Plug
Gasket
6 Screws
(3 sizes included)
Mounting Strap
Mounting Bolt
2 Wire
Connectors
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Mode: On-Time Works: Day Night
Test
5 Seconds x x
Auto
1, 5, or 20 Min x
Manual
To Dawn* x
Dual Light
Level
3, 6 Hr, to Dawn x
AUTO
MANUAL MODE
GUARDIAN PRO
240 SeRieS
240-028-A