Armstrong World Industries 57211 Flooring User Manual


 
ARTEFFECTS
®
Specification Data
Premium Composition Tile
Material
A composition of polyvinyl chloride resin, plasticizers,
stabilizers, fillers and pigments.
Construction and Colors
Color and pattern detail are dispersed uniformly throughout
the thickness of the material. Color pigments are insoluble
in water and resistant to cleaning agents and light.
Size
12 in. x 12 in. (305 mm x 305 mm) tile
Gauge (nominal thickness)
1/8˝ (3.2 mm)
Limitations
These products should not be used in the following areas:
Hospital operating rooms.
Heavy industrial and exterior areas.
Commercial kitchens and commercial food processing
areas.
Where pointed spikes such as golf or track shoes will be
used.
Where the floor will be subjected to unusually
concentrated static or dynamic loads.
NOTE: Concentrated static and dynamic loads such as
hospital beds, roll-out bleachers, portable x-ray machines,
etc., may visibly damage resilient as well as other types of
floor coverings. For questions regarding product
suitability and detailed instructions for floor preparation
and installation in these applications, please contact
Armstrong.
Suitable for Application Over
Concrete, terrazzo, and other dry, structurally sound
monolithic subfloors, which are suspended, on grade or
below grade.
Suspended wood subfloor construction with approved
wood underlayments, and a minimum of 18 in. (45.7 cm)
well-ventilated air space below.
Most metal floors and most existing single-layer resilient
floors on approved underlayments.
Radiant-heated subfloors with a maximum surface
temperature of 85˚ F (29˚ C).
Unsuitable for Application Over
Subfloors where excessive moisture or alkali is present.
Sleeper-constructed wood subfloors, on grade or below
grade.
Lightweight aggregate concrete subfloors having a
density of less than 90 lbs. per cu. ft. (1441 kg/m
3
) or
cellular concrete having a plastic (wet) density less than
100 lbs. per cu. ft. (1602 kg/m
3
) [94 lbs. per cu. ft.
(1506 kg/m
3
) dry weight], or concrete having a
compressive strength of less than 3500 psi (24 MPa).
Concrete slabs with heavy static and/or dynamic loads
should have higher design strengths and densities
calculated to accommodate such loads.
Concrete curing agents, sealers, hardeners, or parting
agents should be removed.
TECHNICAL DATA
Shipping Weight
63 lbs./carton (29 kg)
Packaging
Tiles per carton – 45, 45 sq. ft.
Gloss (typical value)
60 degrees specular: 20 - 40
Reference Specifications
ASTM F 1066, Class 3 – surface pattern
Static Load Limit
ASTM F 970
125 lbs./sq. in. (8.8 kg/cm
2
)
NOTE: Floors should be protected from sharp-point loads
and heavy static loads. High-heeled traffic [1000 psi
(70.3 kg/cm
2
) or more] may visibly damage wood, resilient
and other floor coverings.
Comparative Subjective Property Ratings
Durability – Good
Maintainability – Good
Resilience – Good
Subjective ratings (excellent, very good, good, fair) are in
relation to other Armstrong commercial resilient floors.
Ratings are not directly related to any one test. They are
broadly based on tests and experience of Armstrong
Research and Development under varying conditions and
circumstances. These ratings should not be used for
comparison to ratings used by other manufacturers to rank
their own products.
Fire Test Data
ASTM E 648 Flooring Radiant Panel Critical Radiant Flux –
0.45 watts/cm
2
or more – Class I
ASTM E 662 Smoke Chamber Specific Optical Smoke
Density – 450 or less
Numerical flammability ratings alone may not define the
performance of the product under actual fire conditions.
These ratings are provided only for use in the selection of
products to meet the specified limits.
INSTALLATION
Job Conditions
Subfloors/underlayments shall be dry, clean, and smooth.
They shall be free from paint, varnish, solvents, wax, oil,
existing adhesive residue, or other foreign matter.
For more detailed requirements of concrete, wood and
metal subfloors, as well as wood and trowelable
underlayments, refer to Armstrong Guaranteed Installation
Systems manual, F-5061. Calcium Chloride Tests for
moisture must be conducted. Armstrong offers a guideline
of a maximum acceptable moisture emission level of 5.0
lbs. per 1000 sq. ft. per 24 hours. Bond Tests should also
be conducted for compatibility with the substrate. When
testing for alkalinity, the allowable readings for the
installation of Armstrong flooring are 5 to 9 on the pH scale.
Temperature shall be maintained at a minimum of 65˚ F
(18˚ C) and a maximum of 100˚ F (38˚ C) for 48 hours prior
to installation, during installation and 48 hours after
completion. A minimum temperature of 55˚ F (13˚ C) shall
be maintained thereafter. Condition all flooring materials
and adhesives to room temperature at least 48 hours prior
to starting installation. Protect all materials from the direct
flow of heat from hot-air registers, radiators, or other
heating fixtures and appliances.
Procedure
These products should be installed with the following
adhesives:
*S-89 may only be used over steel, stainless steel,
aluminum and lead.
NOTE: Install each ARTEFFECTS tile with the arrows
pointing in the same direction for a nondirectional look.
Detailed instructions may be found in the Armstrong
Guaranteed Installation Systems manual, F-5061.
MAINTENANCE
These products are designed to be maintained by
traditional resilient flooring maintenance methods, which
include the use of polishes, spray-buffing techniques and
appropriate high–speed maintenance systems.
Initial Maintenance Immediately After Installation
Sweep or vacuum thoroughly.
Damp mop with a dilute neutral detergent solution such
as Armstrong S-485 Floor Cleaner – carefully wiping up
black marks and excessive soil.
Apply two coats of high quality commercial floor polish
such as Armstrong S-480.
Do not wash, scrub or strip the floor for at least four to
five days after installation.
Preparation for Commercial Use
For specific, ongoing maintenance procedures see
Armstrong Maintenance Recommendations & Procedures
for Commercial Resilient Flooring booklet, F-8663.
WARRANTIES
Armstrong warrants its regular (first quality) commercial
floors and wall base to be free from manufacturing defects
and warrants the installation integrity for five years from the
date of purchase, if installed according to the Armstrong
Guaranteed Installation Systems manual, F-5061. This
warranty extends only to the original end-user. See
Armstrong Commercial Floor Warranty
, F-3349 or visit
armstrong.com for warranty details, limitations
and exclusions.
WARNING: EXISTING IN-PLACE RESILIENT FLOOR
COVERING AND ASPHALTIC ADHESIVES. DO NOT
SAND, DRY SWEEP, DRY SCRAPE, DRILL, SAW,
BEADBLAST, OR MECHANICALLY CHIP OR PULVERIZE
EXISTING RESILIENT FLOORING, BACKING, LINING
FELT, ASPHALTIC “CUTBACK” ADHESIVE, OR OTHER
ADHESIVE.
These existing in-place products may contain asbestos
fibers and/or crystalline silica.
Avoid creating dust. Inhalation of such dust is a cancer
and respiratory tract hazard.
Smoking by individuals exposed to asbestos fibers greatly
increases the risk of serious bodily harm.
Unless positively certain that the existing in-place product
is a non-asbestos-containing material, you must presume it
contains asbestos. Regulations may require that the
material be tested to determine asbestos content and may
govern removal and disposal of material.
See current edition of the Resilient Floor Covering Institute
(RFCI) publication Recommended Work Practices for
Removal of Resilient Floor Coverings for instructions on
removing all resilient floor covering structures or contact
your retailer or Armstrong World Industries, Inc. 1 800 233
3823.
The floor covering or adhesive in this package does NOT
contain asbestos.
NOTE: Darker-colored patterns may be susceptible to
scratch whitening. These colors may require more frequent
maintenance if used in field areas: 57207, 57211, 57213.
Subfloor Concrete
Wood
Underlayment
Ceramic,
Marble,
Terrazzo
Metal
Existing
Resilient
Floor
Adhesive S-89
S-515
S-700
S-750
S-515
S-700
S-750
S-89
S-515
S-700
S-750
S-89*
S-700
S-515
S-750
Tile-On
MEMBER / MEMBRE
C
O
N
S
E
I
L
D
U
B
Â
T
I
M
E
N
T
D
U
R
A
B
L
E
D
U
C
A
N
A
D
A
C
A
N
A
D
A
G
R
E
E
N
B
U
I
L
D
I
N
G
C
O
U
N
C
I
L
ISO 9001
Visit armstrong.com/vct • Call 1 877 ARMSTRONG
The knoweledge and technical support
you need to bring your vision to life.
Visit armstrong.com/flooring or
Call 1 877 ARMSTRONG (276 7876)
Choose option 2 to:
Talk to a TechLine Flooring Expert
Contact your Local Armstrong Flooring Representative
Order Samples and Literature
Printed in United States of America.
© 2009 AWI Licensing Company
FloorScore
is a trademark of the Resilient Floor Covering
Institute. LEED
®
is a registered trademark of the United
States Green Building Council. All other trademarks owned
by AWI Licensing Company. LEED
®
and the Armstrong Logo
are registered in the United States and Canada. Armstrong
®
and ARTEFFECTS
®
are registered in the United States only.
F-8242-509
LEED eligible under
Credit EQ4.3 for
Indoor Air Quality
Quality
Management
Standard